Transient electroretinographic abnormalities that mimic those of KCNV2 retinopathy: a case report.

Kaizuka Chihiro, Hayashi Takaaki, Mizobuchi Kei, Kubota Masaomi, Ueno Shinji, Nakano Tadashi

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: The purpose of this report was to describe the case of a 68-year-old male patient with stage IV colon cancer who exhibited electroretinographic abnormalities that are similar to those of KCNV2 retinopathy.

METHODS

The patient presenting with photophobia, reduced visual acuity, and poor general conditions, the onset of which occurred ten days before presentation, was examined using fundoscopy, full-field electroretinography, blood tests, and abdominal computed tomography.

RESULTS

The patient's decimal best-corrected visual acuity (BCVA) was 0.4 in each eye. Fundoscopy showed bull's eye-like maculopathy in both eyes. Electroretinographic findings were similar to the characteristic findings of KCNV2 retinopathy: Rod electroretinogram showed delayed and preserved b-wave amplitudes; bright-flash electroretinogram showed double troughs of a-waves; b/a ratios shown by bright-flash electroretinogram were higher than those shown by standard-flash electroretinogram; and both cone and 30-Hz flicker electroretinograms showed extinguished responses. His serum potassium level increased to 6.2 mmol/L (normal range 3.6-4.8 mmol/L) owing to hydronephrosis resulting from disseminated carcinoma. After performing an emergency surgery to treat this condition, the serum potassium level immediately decreased to a normal range. Eleven days after presentation, rod and standard/bright-flash electroretinography showed improvement in the implicit time of the rod b-waves and the a-waves. Unexpectedly, the responses recorded by cone and 30-Hz flicker electroretinography became normal. The symptoms and maculopathy disappeared, and his BCVA improved to 1.2.

CONCLUSIONS

The abnormal electroretinographic findings might be associated with the transient increase in serum potassium level.

Для цитирования: Kaizuka Chihiro, Hayashi Takaaki, Mizobuchi Kei, Kubota Masaomi, Ueno Shinji, Nakano Tadashi. Transient electroretinographic abnormalities that mimic those of KCNV2 retinopathy: a case report.. Documenta ophthalmologica. Advances in ophthalmology. 2021. DOI: 10.1007/s10633-021-09828-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.