m+Medelevator.RU
← Поиск публикаций
Peritoneal dialysis international : journal of the International Society for Peritoneal Dialysis · 2025

Comparison of carbon emissions, water use, and dialysis waste between incremental and full-dose peritoneal dialysis: A cohort study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Nicdao Mary Ann, Wong Germaine, Manera Karine, Sud Kamal, Daraoay Maria, Jaure Allison, Hanson Scott, Barraclough Katherine A, Cho Yeoungjee, Chau Katrina, Howell Martin

Аннотация

IntroductionIncremental peritoneal dialysis (PD) may confer environmental benefits compared to full-dose PD due to reduced resource use. We aimed to quantify and compare carbon emissions, water consumption, and waste generation between incremental and full-dose PD in a cohort of incident PD patients.MethodsWe compared environmental metrics, including carbon emissions, water consumption, and waste generation between incremental and full-dose PD, using prospectively collected data between June 2019 and May 2024 at the Western Renal Service, Sydney, Australia. Carbon emissions were quantified using standardized coefficients from a published life-cycle analysis, while water and waste volumes were estimated using literature-based assumptions. Group comparisons were conducted using the Mann-Whitney U test, with a two-sided p-value <0.05 considered statistically significant.ResultsAmong 365 incident patients (187 incremental, 178 full-dose), followed for a median of 20 months (interquartile range 13-37), incremental PD had lower median annual per-patient carbon dioxide equivalent emissions (1016 vs. 1360 kg), blue water consumption (24,090 vs. 25,548 L), landfill waste (212 vs. 271 kg), gray water generation (8213 vs. 10,549 L), and recycling volume (73 vs. 131 kg), compared to full-dose PD (all p < 0.001). Incremental PD yielded estimated savings of 201,087 kg carbon dioxide equivalent emissions, over 5 million liters of blue water, 1.8 million liters of gray water, 27,223 kg of landfill waste, and 16,219 kg of recyclable materials.ConclusionIncremental PD was associated with a lower environmental impact than full-dose PD, highlighting its potential contribution to environmentally sustainable dialysis care.

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты