Intracardiac Right-to-Left Shunt Impeding Liberation From Veno-Venous Extracorporeal Membrane Oxygenation: Two Case Studies.

Gillon Stuart A, Barrett Nicholas A, Ioannou Nicholas, Camporota Luigi, Victor Kelly, Gowland Abigail, Meadows Christopher I S, Langrish Christopher, Tricklebank Stephen, Wyncoll Duncan

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVES

Veno-venous extracorporeal membrane oxygenation is an increasingly used form of advanced respiratory support, but its effects on the physiology of the right heart are incompletely understood. We seek to illustrate the impact of veno-venous extracorporeal membrane oxygenation return blood flow upon the right atrium by considering the physiologic effects during interatrial shunting.

PATIENTS: Two veno-venous extracorporeal membrane oxygenation patients in whom an extracorporeal membrane oxygenation induced right-to-left interatrial shunt appears to have created a barrier to liberation from extracorporeal support.

CONCLUSIONS

Veno-venous extracorporeal membrane oxygenation return flow generates a high-pressure jet that has potential to exert focal pressure upon the intra-atrial septum. In patients with potential for interatrial flow, this may lead to a right-to-left shunt, which becomes physiologically apparent only when sweep gas flow is ceased.

Для цитирования: Gillon Stuart A, Barrett Nicholas A, Ioannou Nicholas, Camporota Luigi, Victor Kelly, Gowland Abigail, Meadows Christopher I S, Langrish Christopher, Tricklebank Stephen, Wyncoll Duncan. Intracardiac Right-to-Left Shunt Impeding Liberation From Veno-Venous Extracorporeal Membrane Oxygenation: Two Case Studies.. Critical care medicine. 2016. DOI: 10.1097/ccm.0000000000001619.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.