The international journal of cardiovascular imaging · 2015
The advantages of live/real time three-dimensional transesophageal echocardiography during assessments of pulmonary stenosis.
Сравнительное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Kemaloğlu Öz Tuğba, Özpamuk Karadeniz Fatma, Akyüz Şükrü, Ünal Dayı Şennur, Esen Zencirci Aycan, Atasoy Işıl, Ösken Altuğ, Eren Mehmet
Аннотация
This report sought to compare live/real-time three-dimensional transesophageal echocardiography (3D-TEE) with two-dimensional transesophageal echocardiography (2D-TEE) and to determine whether there are advantages to using 3D-TEE on patients with pulmonary stenosis (PS). Sixteen consecutive adult patients (50 % male and 50 % female; mean age 33 ± 13.4 years) with PS and indications of TEE were prospectively enrolled in this study. Following this, initial 2D-TEE and 3D-TEE examinations were performed, and 3D-TEE images were analyzed using an off-line Q-lab software system. Finally, the 2D-TEE and 3D-TEE findings were compared. In the present study, 3D-TEE allowed us to obtain the en face views of pulmonary valves (PVs) in all but one patient. While this patient was without a PV due to a previous tetralogy of Fallot operation, we could detect the type of PV in the other 15 (93.7 %) patients by using 3D-TEE. Due to poor image quality, the most stenotic area was not measurable in only one (6.2 %) of the patients. In eight (50 %) of the patients, severity and localization of stenosis were more precisely determined with 3DTEE than with 2D-TEE. The PVs' maximal annulus dimensions were found to be significantly larger when they were measured using 3D modalities. This study provides evidence of the incremental value of using 3D-TEE rather than 2D-TEE during assessments of PS, specifically in cases where special conditions (pregnancy, pulmonary regurgitation, and concomitant atrial septal defects) cause recordings of the transvalvular peak gradient to be inaccurate. Therefore, 3D-TEE should be used as a complementary imaging tool to 2D-TEE during routine echocardiographic examinations.
Предметные рубрики MeSH
AdultEchocardiography, Doppler, ColorEchocardiography, Three-DimensionalEchocardiography, TransesophagealFeasibility StudiesFemaleHemodynamicsHumansImage Processing, Computer-AssistedMaleMiddle AgedObserver VariationPredictive Value of TestsPrognosisPulmonary ValvePulmonary Valve StenosisReproducibility of ResultsSeverity of Illness IndexTime FactorsYoung Adult