MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/labmed/lmx063

Медицинская библиотека · Laboratory medicine · 2017

Loop-Mediated Isothermal Amplification on Crude DNA as a Point-of-Care Test for the Diagnosis of Mycoplasma-Related Vaginitis During Early Pregnancy.

Wang Yichao, Zhang Bumei, Sun Yan, Liu Yunde, Gu Yajun

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Mycoplasma-related vaginitis gradually has been growing as a threat in adults-genitourinary infection contributes to funisitis, spontaneous abortion, and low birth weight. Until now, use of loop-mediated isothermal amplification (LAMP) to detect Ureaplasma urealyticum (UU), Mycoplasma hominis (MH), or Mycoplasma genitalium (MG) has been reported by some researchers. However, previous studies focused on purified DNA as the template for LAMP assay, which is usually extracted via commercial kit.

METHODS

We developed a LAMP assay for rapid detection of UU, MH, and MG genital mycoplasmas using a simple boiling method for DNA extraction, in a cohort of pregnant women with mycoplasma-related vaginitis. We monitored amplicons with the naked eye using SYBR Green I.

RESULTS

The cohort in our study showed a prevalence of 22.6% in pregnant women, as detected by UU-LAMP assay. Compared to the polymerase chain reaction (PCR) test with purified DNA, the sensitivity of the UU-LAMP in clinical specimens with crude DNA was 87.5% (95% confidence interval [CI], 64.6%->99.9). For crude DNA specimens, UU-LAMP was more sensitive and reliable than PCR, with a higher agreement rate (96.8%) and Youden index value (0.88).

CONCLUSIONS

As a point-of-care test, LAMP is a useful, specific, and efficient way to detect genital mycoplasmas in resource-limited settings, especially for crude DNA.

Для цитирования: Wang Yichao, Zhang Bumei, Sun Yan, Liu Yunde, Gu Yajun. Loop-Mediated Isothermal Amplification on Crude DNA as a Point-of-Care Test for the Diagnosis of Mycoplasma-Related Vaginitis During Early Pregnancy.. Laboratory medicine. 2017. DOI: 10.1093/labmed/lmx063.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.