The Accuracy of Large Loop Excision of the Transformation Zone Specimen Dimensions in Determining Volume: A Multicentric Prospective Observational Study.

Carcopino Xavier, Mancini Julien, Prendiville Walter, Gondry Jean, Chevreau Julien, Lamblin Gery, Atallah Anthony, Lavoue Vincent, Caradec Claire, Baldauf Jean-Jacques, Bryand Angélique, Henno Sébastien, Agostini Aubert, Douvier Serge, Jarniat Adelaide, Riethmuller Didier, Mendel Anne, Brun Jean-Luc, Rakotomahenina Hajanarina, Preaubert Lise

СтатьяМногоцентровое исследованиеНаблюдательное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The aim of the study was to determine which mathematical formula of specimen dimensions is the most accurate method of determining volume of the excised specimen at loop excision of the transformation zone.

MATERIALS AND

METHODS

A multicenter prospective observational study was conducted. A total of 258 patients who had a loop excision of the transformation zone performed as treatment of cervical intraepithelial neoplasia 2-3 were included. The dimensions and the volume of the specimen were measured at the time of the procedure, before formaldehyde fixation. The volume was measured by immersing the specimen in a graduated cylinder using Archimedes fluid displacement technique. The measured volume was compared with the calculated volume using different volume formulas, that is, a cone, a cylinder, a parallelepiped, and a hemiellipsoid. The main outcome measure was the relationship between calculated volume (using the dimensions of thickness, length, and circumference) and the measured volume of the specimen.

RESULTS

The mean (SD) thickness, length, and circumference of specimens were 8.8 mm (3.8), 12.7 mm (5.9), and 45.7 mm (16.8), respectively. The mean (SD) measured volume was 2.53 (1.49) mL. Using the formula for the volume of a cone, a cylinder, a parallelepiped and a hemiellipsoid, estimated volumes were 1.03 mL (1.22), 3.10 mL (3.65), 6.20 mL (7.31), and 2.07 mL (2.44), respectively. The highest intraclass correlation coefficient between measured and calculated volume was observed when using the formula for the volume of a hemiellipsoid specimen (0.47, 95% CI = 0.36-0.56).

CONCLUSIONS

The hemiellipsoid formula is the most accurate determinant of the excised volume. Other formulas do not allow for an accurate estimation of the excised volume.

Для цитирования: Carcopino Xavier, Mancini Julien, Prendiville Walter, Gondry Jean, Chevreau Julien, Lamblin Gery, Atallah Anthony, Lavoue Vincent, Caradec Claire, Baldauf Jean-Jacques, Bryand Angélique, Henno Sébastien, Agostini Aubert, Douvier Serge, Jarniat Adelaide, Riethmuller Didier, Mendel Anne, Brun Jean-Luc, Rakotomahenina Hajanarina, Preaubert Lise. The Accuracy of Large Loop Excision of the Transformation Zone Specimen Dimensions in Determining Volume: A Multicentric Prospective Observational Study.. Journal of lower genital tract disease. 2017. DOI: 10.1097/lgt.0000000000000283.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.