Supraglottic Airway Devices and Effect on Voice-Comparison of LMA Proseal and i-gel: Double-Blind Randomized Clinical Trial.

Vaidya Shriram, Kundra Pankaj, Gopalakrishnan Surianarayanan, Parida Pradiptakumar, Yuvaraj Kotteeswaran, Mohan P Manju

Сравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

Laryngeal mask airway (LMA) is an important alternative to endotracheal intubation for all professional voice users undergoing surgery. However, dysphonia is a known complication of LMA Proseal (PLMA) use. The i-gel airway (IGA) provides adequate airway seal without the need for an inflatable cuff. Hence, it helps to minimize the risk of tissue compression. This study compares effect of PLMA and IGA on voice at 24th hour after anesthesia.

DESIGN

This is a double-blind randomized clinical trial.

METHODS

Ninety anesthesiologists class 1 adults scheduled for surgeries lasting up to 60-120 minutes were included in the study. Participants were randomly allocated to group PLMA (n = 43) and group IGA (n = 43). Cuff pressure was monitored and maintained at just seal pressure in group PLMA. Voice was evaluated using perceptive and acoustic analysis (jitter, shimmer, and harmonics-to-noise ratio [HNR]) preoperatively and at 24th hour after anesthesia. Voice of patients with pharyngolaryngeal complaints was categorized into rough, breathy, asthenic, strain, or normal pattern.

RESULTS

Acoustic parameters jitter, shimmer, and HNR deteriorated significantly in both group PLMA and IGA albeit the change being comparable. Incidence of pharyngolaryngeal complaints was similar in both the groups. A total of 10% patients in group PLMA and 12.5% in group IGA developed breathy voice significant deterioration in all acoustic variables at 24th postoperative hour, but differences were not significant between group PLMA and group IGA.

CONCLUSIONS

PLMA and IGA both produce comparable and significant deterioration in acoustic variables at 24th hour after short duration general anesthesia.

Для цитирования: Vaidya Shriram, Kundra Pankaj, Gopalakrishnan Surianarayanan, Parida Pradiptakumar, Yuvaraj Kotteeswaran, Mohan P Manju. Supraglottic Airway Devices and Effect on Voice-Comparison of LMA Proseal and i-gel: Double-Blind Randomized Clinical Trial.. Journal of voice : official journal of the Voice Foundation. 2015. DOI: 10.1016/j.jvoice.2015.06.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.