MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpba.2017.01.035

Медицинская библиотека · Journal of pharmaceutical and biomedical analysis · 2017

Fabrication of a novel hemin-based monolithic column and its application in separation of protein from complex bio-matrix.

Jiang Xiaoya, Zhang Doudou, Li Xueying, Wang Xixi, Bai Ligai, Liu Haiyan, Yan Hongyuan

СтатьяПеревод в очереди

Аннотация

A novel polymer-based monolithic column was prepared via redox initiation system within the confines of a stainless steel column with 4.6mm i.d. In the processes, hemin and lauryl methacrylate were used as co-monomers; ethylene dimethacrylate as crosslinking agent; n-butyl alcohol, ethanediol, and N, N-dimethylformamide as tri-porogens; benzoyl peroxide and N, N-dimethyl aniline as redox initiation system. The resulting polymer-based monolithic columns were characterized by scanning electron microscopy, nitrogen adsorption-desorption instrument, and mercury intrusion porosimeter, respectively. The results illustrated that the improved monolith had relative uniform porous structure, good permeability, and low back pressure. Aromatic compounds were used to test the chromatographic behavior of the monolith, resulting in highest column efficiency of 19 880 plates per meter with reversed-phase mechanism. Furthermore, the homemade monolith was used as the stationary phase of high performance liquid chromatography to separate proteins from complex bio-matrix, including human plasma, egg white, and snailase. The results showed that the monolithic column occupied good separation ability with these complex bio-samples. Excellent specific character of the homemade hemin-based monolith was that it could simultaneously remove high-abundance proteins (including human serum albumin, immunoglobulin G, and human fibrinogen) from human plasma and separate other proteins to different fractions.

Для цитирования: Jiang Xiaoya, Zhang Doudou, Li Xueying, Wang Xixi, Bai Ligai, Liu Haiyan, Yan Hongyuan. Fabrication of a novel hemin-based monolithic column and its application in separation of protein from complex bio-matrix.. Journal of pharmaceutical and biomedical analysis. 2017. DOI: 10.1016/j.jpba.2017.01.035.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.