MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1017/s1047951107000133

Медицинская библиотека · Cardiology in the young · 2007

Does a ventriculotomy have deleterious effects following palliation in the Norwood procedure using a shunt placed from the right ventricle to the pulmonary arteries?

Graham Eric M, Atz Andrew M, Bradley Scott M, Scheurer Mark A, Bandisode Varsha M, Laudito Antonio, Shirali Girish S

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

A recent modification to the Norwood procedure involving a shunt placed directly from the right ventricle to the pulmonary arteries may improve postoperative haemodynamics. Concerns remain, however, about the potential problems produced by the required ventriculotomy.

METHODS

We compared 76 patients with hypoplastic left heart syndrome who underwent the Norwood procedure, 35 receiving a modified Blalock-Taussig shunt and the remaining 41 a shunt placed directly from the right ventricle to the pulmonary arteries. We reviewed their subsequent progress through the second stage of palliation. A single observer graded right ventricular function, and the severity of tricuspid regurgitation, based on blinded review of the most recent echocardiograms prior to the second stage of palliation.

RESULTS

At the time of catheterization prior to the second stage, patients with a shunt placed from the right ventricle to the pulmonary arteries, rather than a modified Blalock-Taussig shunt, had higher arterial diastolic blood pressure, at 44 versus 40 millimetres of mercury, p equal to 0.02, lower ventricular end diastolic pressures, at 8 versus 11 millimetres of mercury, p equal to 0.0002, and larger pulmonary arteries as judged using the Nakata index, at 270 versus 188 millimetres squared per metres squared, p equal to 0.009. There was no difference in qualitative ventricular systolic function or tricuspid regurgitation between groups. No differences were found between groups during the hospitalization following the second stage of palliation. A trend towards improved survival to the second stage was seen following the construction of a shunt from the right ventricle to the pulmonary arteries.

CONCLUSIONS

Construction of a shunt from the right ventricle to the pulmonary arteries is associated with lower right ventricular end diastolic pressures, larger pulmonary arterial size, and higher systemic arterial diastolic pressures. No apparent deleterious effects of the right ventriculotomy were observed in terms of qualitative ventricular systolic function or tricuspid regurgitation.

Для цитирования: Graham Eric M, Atz Andrew M, Bradley Scott M, Scheurer Mark A, Bandisode Varsha M, Laudito Antonio, Shirali Girish S. Does a ventriculotomy have deleterious effects following palliation in the Norwood procedure using a shunt placed from the right ventricle to the pulmonary arteries?. Cardiology in the young. 2007. DOI: 10.1017/s1047951107000133.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.