Choriocapillaris microvasculature dysfunction in systemic hypertension.

Chua Jacqueline, Le Thu-Thao, Tan Bingyao, Ke Mengyuan, Li Chi, Wong Damon Wing Kee, Tan Anna C S, Lamoureux Ecosse, Wong Tien Yin, Chin Calvin Woon Loong, Schmetterer Leopold

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

We examined the choriocapillaris microvasculature using a non-invasive swept-source optical coherence tomography angiography (SS-OCTA) in 41 healthy controls and 71 hypertensive patients and determined possible correlations with BP and renal parameters. BP levels, serum creatinine and urine microalbumin/creatinine ratio (MCR) specimens were collected. The estimated glomerular filtration rate (eGFR) was calculated based on CKD-EPI Creatinine Equation. The main outcome was choriocapillaris flow deficits (CFD) metrics (density, size and numbers). The CFD occupied a larger area and were fewer in number in the hypertensive patients with poor BP control (407 ± 10 µm2; 3260 ± 61) compared to the hypertensives with good BP control (369 ± 5 µm2; 3551 ± 41) and healthy controls (365 ± 11 µm2; 3581 ± 84). Higher systolic BP (β = 9.90, 95% CI, 2.86-16.93), lower eGFR (β =  - 0.85; 95% CI, - 1.58 to - 0.13) and higher urine MCR (β = 1.53, 95% CI, 0.32-2.78) were associated with larger areas of CFD. Similar significant associations with systolic BP, eGFR and urine MCR were found with number of CFD. These findings highlight the potential role of choriocapillaris imaging using SS-OCTA as an indicator of systemic microvascular abnormalities secondary to hypertensive disease.

Для цитирования: Chua Jacqueline, Le Thu-Thao, Tan Bingyao, Ke Mengyuan, Li Chi, Wong Damon Wing Kee, Tan Anna C S, Lamoureux Ecosse, Wong Tien Yin, Chin Calvin Woon Loong, Schmetterer Leopold. Choriocapillaris microvasculature dysfunction in systemic hypertension.. Scientific reports. 2021. DOI: 10.1038/s41598-021-84136-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.