Defining the target value of the coefficient of variation by continuous glucose monitoring in Chinese people with diabetes.

Оценочное исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Mo Yifei, Ma Xiaojing, Lu Jingyi, Shen Yun, Wang Yufei, Zhang Lei, Lu Wei, Zhu Wei, Bao Yuqian, Zhou Jian

Аннотация

AIMS/INTRODUCTION: To define the target value for the percentage coefficient of variation for glucose (%CV) as a measure of glycemic variability (GV) in Chinese diabetes patients.

MATERIALS AND METHODS: This retrospective study included 3,007 diabetes patients who underwent continuous glucose monitoring for 3 days. Type 2 diabetes was divided into groups according to the received treatment: group 1, non-insulinotropic agent (n = 138); group 2, insulinotropic agent (n = 761); group 3, basal insulin therapy (n = 100); group 4, premixed insulin (n = 784); and group 5, intensive insulin therapy (n = 612). Type 1 diabetes patients were included as group 6 (n = 612). %CV and percentage of time per day within, below (3.9mmol/L; TBR3.9 ) and above (10.0 mmol/L) the target glucose range (3.9-10.0 mmol/L) were computed. TBR3.9 ≥4% was defined as excessive hypoglycemia.

RESULTS: Type 2 diabetes with a premixed or intensive insulin regimen had an increased %CV compared with those receiving oral therapy or basal insulin. The upper limit of %CV in group 1 was 33%, which was adopted as the threshold to define excessive GV. For each treatment group, the percentage of people with TBR3.9 ≥4% was significantly greater in the subgroup with %CV >33% than ≤33% (P < 0.001). In participants who achieved TBR3.9 <4%, the time per day spent within the target glucose range of 3.9-10.0 mmol/L > 70% and time per day above 10.0 mmol/L <25%, the 95th percentile of %CV was 32.70%. Further receiver operating characteristic curve analysis showed that the cut-off values of %CV for predicting TBR3.9 ≥4% varied by the type of diabetes and glycated hemoglobin categories.

CONCLUSIONS: A %CV of 33% was set as the threshold for excess glucose variability in Chinese diabetes patients. Meanwhile, glycated hemoglobin and the type of diabetes should be considered for the goal-setting of %CV.