MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/pace.14587

Медицинская библиотека · Pacing and clinical electrophysiology : PACE · 2022

The jugular approach for leadless pacing: A novel and safe alternative.

Saleem-Talib Shmaila, van Driel Vincent J, Nikolic Tanja, van Wessel Harry, Louman Hellen, Borleffs C Jan Willem, van der Heijden Jeroen, Cox Moniek, Ramanna Hemanth

СтатьяПеревод в очереди

Аннотация

AIMS: To evaluate safety of leadless pacemaker implantation through the internal jugular vein in a larger cohort with longer follow-up. Moreover, feasibility of non-apical pacing as well as relation between pacing site and QRS duration were assessed.

METHODS

Eighty Two consecutive patients, who received a leadless pacemaker though the internal jugular vein, were included. Electrical parameters were measured at regular follow-up and any complications were registered. Paced QRS interval was compared for three pacing sites, RVOT, RV mid septum, and RV apical septum.

RESULTS

In all patients, the leadless pacemaker was implanted successfully. In 69 patients, the device was implanted in a non-apical position. In 71% of cases, the device could be deployed at first attempt. The median fluoroscopy time was 4.4 min (range 0.9-51) The paced QRS interval was significantly narrower for non-apical pacing sites compared to apical pacing si 156  vs. 179 ms. p = .04, respectively. During mean follow-up of 16 months (range 0-43 months), electrical parameters remained stable. Two complications occurred, which could be resolved during the implant procedure. There were no access site related complications.

CONCLUSION

The jugular approach for leadless pacemaker implantation is feasible and may avoid vascular complications. It facilitates non-apical positioning of leadless pacemakers leading to a narrower paced QRS interval. The jugular approach allows for immediate post procedural ambulation.

Для цитирования: Saleem-Talib Shmaila, van Driel Vincent J, Nikolic Tanja, van Wessel Harry, Louman Hellen, Borleffs C Jan Willem, van der Heijden Jeroen, Cox Moniek, Ramanna Hemanth. The jugular approach for leadless pacing: A novel and safe alternative.. Pacing and clinical electrophysiology : PACE. 2022. DOI: 10.1111/pace.14587.