Efficacy and safety of a minimalistic balloon aortic valvuloplasty strategy in a centre without heart surgery.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bruno Matteo, Iannopollo Gianmarco, Cardelli Laura Sofia, Capecchi Alessandro, Lanzilotti Valerio, Verardi Roberto, Pedone Chiara, Nobile Giampiero, Casella Gianni

Аннотация

BACKGROUND: Balloon aortic valvuloplasty (BAV) is a palliative tool for patients with symptomatic severe aortic stenosis (AS) at prohibitive risk for surgery or as a bridge to surgical aortic valve replacement (SAVR) or transcatheter aortic valve replacement (TAVR). BAV is traditionally performed in hospitals with onsite cardiac surgery due to its potential complications.

AIMS: The aim of this study was to evaluate the safety of BAV procedures performed by trained high-volume operators in a centre without onsite surgery and to assess the effect of a minimalistic approach to reduce periprocedural complications.

METHODS: From 2016 to 2021, 187 BAV procedures were performed in 174 patients. Patients were elderly (mean age: 85.0±5.4 years) and had high-risk (mean European System for Cardiac Operative Risk Evaluation score [EuroSCORE] II: 10.1±9.9) features. According to the indications, 4 cohorts were identified: 1) bridge to TAVR (n=98; 56%); 2) bridge to SAVR (n=8; 5%); 3) cardiogenic shock (n=11; 6%); and 4) palliation (n=57; 33%). BAV procedures were performed using the standard retrograde technique via femoral access in 165 patients (95%), although radial access was used in 9 patients (5%). Ultrasound-guided vascular puncture was performed in 118 patients (72%) and left ventricular pacing was administered through a stiff guidewire in 105 cases (60%).

RESULTS: BAV safety was confirmed by 1 periprocedural death (0.6%), 1 intraprocedural stroke (0.6%), 2 major vascular complications (1%) and 9 minor vascular complications (5%). Nine cases of in-hospital mortality occurred (5%), predominantly in patients with cardiogenic shock.

CONCLUSIONS: BAV is a safe procedure that can be performed in centres without onsite cardiac surgery using a minimalistic approach that can reduce periprocedural complications.