DOI 10.1016/j.clinimag.2008.12.007

Медицинская библиотека · Clinical imaging · 2009

Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.

Deng Kai, Sun Cong, Liu Cheng, Ma Rui

СтатьяПеревод в очереди

Аннотация

PURPOSE: To assess the feasibility of visualizing hand and foot tendons by dual-energy computed tomography (CT).

METHODS AND MATERIALS: Twenty patients who suffered from hand or feet pains were scanned on dual-source CT (Definition, Forchheim, Germany) with dual-energy mode at tube voltages of 140 and 80 kV and a corresponding ratio of 1:4 between tube currents. The reconstructed images were postprocessed by volume rendering techniques (VRT) and multiplanar reconstruction (MPR). All of the suspected lesions were confirmed by surgery or follow-up studies.

RESULTS

Twelve patients (total of 24 hands and feet, respectively) were found to be normal and the other eight patients (total of nine hands and feet, respectively) were found abnormal. Dual-energy techniques are very useful in visualizing tendons of the hands and feet, such as flexor pollicis longus tendon, flexor digitorum superficialis/profundus tendon, Achilles tendon, extensor hallucis longus tendon, and extensor digitorum longus tendon, etc. It can depict the whole shape of the tendons and their fixation points clearly. Peroneus longus tendon in the sole of the foot was not displayed very well. The distal ends of metacarpophalangeal joints with extensor digitoium tendon and extensor pollicis longus tendon were poorly shown. The lesions of tendons such as the circuitry, thickening, and adherence were also shown clearly.

CONCLUSION

Dual-energy CT offers a new method to visualize tendons of the hand and foot. It could clearly display both anatomical structures and pathologic changes of hand and foot tendons.

Для цитирования: Deng Kai, Sun Cong, Liu Cheng, Ma Rui. Initial experience with visualizing hand and foot tendons by dual-energy computed tomography.. Clinical imaging. 2009. DOI: 10.1016/j.clinimag.2008.12.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.