High-performance wavelet compression for mammography: localization response operating characteristic evaluation.

Kallergi Maria, Lucier Bradley J, Berman Claudia G, Hersh Marla R, Kim Jihai J, Szabunio Margaret S, Clark Robert A

СтатьяПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПоддержка правительства СШАПеревод в очереди

Аннотация

PURPOSE: To evaluate the accuracy of a visually lossless, image-adaptive, wavelet-based compression method for achievement of high compression rates at mammography.

MATERIALS AND

METHODS

The study was approved by the institutional review board of the University of South Florida as a research study with existing medical records and was exempt from individual patient consent requirements. Patient identifiers were obliterated from all images. The study was HIPAA compliant. An algorithm based on scale-specific quantization of biorthogonal wavelet coefficients was developed for the compression of digitized mammograms with high spatial and dynamic resolution. The method was applied to 500 normal and abnormal mammograms from 278 patients who were 32-85 years old, 85 of whom had biopsy-proved cancer. Film images were digitized with a charge-coupled device-based digitizer. The original and compressed reconstructed images were evaluated in a localization response operating characteristic experiment involving three radiologists with 2-10 years of experience in reading mammograms.

RESULTS

Compression rates in the range of 14:1 to 2051:1 were achieved, and the rates were dependent on the degree of parenchymal density and the type of breast structure. Ranges of the area under the receiver operating characteristic curve were 0.70-0.83 and 0.72-0.86 for original and compressed reconstructed mammograms, respectively. Ranges of the area under the localization response operating characteristic curve were 0.39-0.65 and 0.43-0.71 for original and compressed reconstructed mammograms, respectively. The localization accuracy increased an average of 6% (0.04 of 0.67) with the compressed mammograms. Localization performance differences were statistically significant with P = .05 and favored interpretation with the wavelet-compressed reconstructed images.

CONCLUSION

The tested wavelet-based compression method proved to be an accurate approach for digitized mammography and yielded visually lossless high-rate compression and improved tumor localization.

Для цитирования: Kallergi Maria, Lucier Bradley J, Berman Claudia G, Hersh Marla R, Kim Jihai J, Szabunio Margaret S, Clark Robert A. High-performance wavelet compression for mammography: localization response operating characteristic evaluation.. Radiology. 2006. DOI: 10.1148/radiol.2381040896.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.