Percutaneous closure of inter-atrial communications (atrial septal defect and patent foramen ovale): single-centre experience and mid-term follow-up.
Аннотация
BACKGROUND
Percutaneous closure of atrial septal defect (ASD) and patent foramen ovale (PFO) are increasingly being performed. Effective closure rate depends on the anatomy of the interatrial septum and the device used, but its relationship with outcome is poorly described. This study aimed at evaluating: (1) effective ASD and PFO closure rate, (2) factors related with effective closure rate, and (3) factors related with mid-term outcome.
METHODS
All patients who underwent percutaneous ASD or PFO closure at Jessa Hospital Hasselt between April 2002 and February 2014 were enrolled. Closure rate was evaluated using consecutive contrast echocardiography studies. Adverse events were defined as a composite of all-cause mortality, hospitalization for heart failure, atrial arrhythmias and thrombo-embolic event.
RESULTS
One-hundred and two patients (52 +/- 12 y, 42% male, 75 PFO and 27 ASD) were included in the study. Moderate residual shunt was present in 6% and 10% 6 years after ASD and PFO closure, respectively. The presence of an aneurysmatic interatrial septum was associated with residual shunt after PFO closure (HR 0.57 95% CI 0.33-0.96; P=0.031). Pulmonary hypertension (HR 1.09 95% CI 1.01-1.17; P=0.017) and a history of atrial arrhythmias in ASD (HR 4.28 95% CI 1.06-17.40; P=0.046) and age at closure (HR 1.09 95% CI 1.02-1.16; P=0.012) in PFO patients were related with adverse events. The highest rate of adverse events was observed after placement of a Helex Septal Occluder. Amplatzer and Occlutech devices yielded higher effective closure rates.
CONCLUSIONS
Effective closure rates were acceptable 6 years after ASD and PFO closure. The presence of an aneurysmatic septum is associated with residual shunting after PFO closure. Pulmonary hypertension in ASD and older age at closure in PFO are associated with adverse outcome. Adverse events are more frequent with the Helex occluder and effective closure rate depends on the device used.