Ossiculoplasty on Isolated Malleus Fractures: A Human Temporal Bone Study Using Laser Doppler Vibrometry.

Niklasson Anders, Rönnblom Anton, Muyshondt Pieter, Dirckx Joris, von Unge Magnus, Tano Krister

СтатьяПеревод в очереди

Аннотация

HYPOTHESIS: In the literature several surgical methods have been reported that aim to improve hearing in patients with isolated malleus fractures; however, it is still not clear which method gives the best results.

BACKGROUND

In this study, laser Doppler vibrometry (LDV) was used to compare the outcome of different surgical methods on malleus fractures in fresh frozen human temporal bones.

METHODS

Fractured malleus shafts of defrosted human temporal bones were repaired with bone cement, with a malleus prosthesis from cortical bone, or with a partial ossicular replacement prosthesis (PORP) from cortical bone, and LDV measurements were obtained for analysis.

RESULTS

The best result was achieved with the bone cement only, applied directly at the site of the fracture. The malleus prosthesis and the PORP gave similar results.

CONCLUSION

All three surgical methods gave good results, but when the distal end of the fractured malleus can be attached close to the proximal end, the technique using only cement tends to be the best option. If the parts are too far apart, a malleus prosthesis or a PORP would be good options.

Для цитирования: Niklasson Anders, Rönnblom Anton, Muyshondt Pieter, Dirckx Joris, von Unge Magnus, Tano Krister. Ossiculoplasty on Isolated Malleus Fractures: A Human Temporal Bone Study Using Laser Doppler Vibrometry.. Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology. 2016. DOI: 10.1097/mao.0000000000001086.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.