MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s11999-013-3097-1

Медицинская библиотека · Clinical orthopaedics and related research · 2013

Validation of PROMIS ® Physical Function computerized adaptive tests for orthopaedic foot and ankle outcome research.

Hung Man, Baumhauer Judith F, Latt L Daniel, Saltzman Charles L, SooHoo Nelson F, Hunt Kenneth J, National Orthopaedic Foot & Ankle Outcomes Research Network

СтатьяМногоцентровое исследованиеВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

In 2012, the American Orthopaedic Foot & Ankle Society(®) established a national network for collecting and sharing data on treatment outcomes and improving patient care. One of the network's initiatives is to explore the use of computerized adaptive tests (CATs) for patient-level outcome reporting.

QUESTIONS/PURPOSES: We determined whether the CAT from the NIH Patient Reported Outcome Measurement Information System(®) (PROMIS(®)) Physical Function (PF) item bank provides efficient, reliable, valid, precise, and adequately covered point estimates of patients' physical function.

METHODS

After informed consent, 288 patients with a mean age of 51 years (range, 18-81 years) undergoing surgery for common foot and ankle problems completed a web-based questionnaire. Efficiency was determined by time for test administration. Reliability was assessed with person and item reliability estimates. Validity evaluation included content validity from expert review and construct validity measured against the PROMIS(®) Pain CAT and patient responses based on tradeoff perceptions. Precision was assessed by standard error of measurement (SEM) across patients' physical function levels. Instrument coverage was based on a person-item map.

RESULTS

Average time of test administration was 47 seconds. Reliability was 0.96 for person and 0.99 for item. Construct validity against the Pain CAT had an r value of -0.657 (p < 0.001). Precision had an SEM of less than 3.3 (equivalent to a Cronbach's alpha of ≥ 0.90) across a broad range of function. Concerning coverage, the ceiling effect was 0.32% and there was no floor effect.

CONCLUSIONS

The PROMIS(®) PF CAT appears to be an excellent method for measuring outcomes for patients with foot and ankle surgery. Further validation of the PROMIS(®) item banks may ultimately provide a valid and reliable tool for measuring patient-reported outcomes after injuries and treatment.

Для цитирования: Hung Man, Baumhauer Judith F, Latt L Daniel, Saltzman Charles L, SooHoo Nelson F, Hunt Kenneth J, National Orthopaedic Foot & Ankle Outcomes Research Network. Validation of PROMIS ® Physical Function computerized adaptive tests for orthopaedic foot and ankle outcome research.. Clinical orthopaedics and related research. 2013. DOI: 10.1007/s11999-013-3097-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.