MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/mnm.0000000000002079

Медицинская библиотека · Nuclear medicine communications · 2025

Sparse-view reconstruction and noise reduction in 99m Tc-prostate specific membrane antigen prostate imaging.

Jamaati Sayna, Dorri Giv Masoumeh, Hong Xiaotong, Sadeghi Ramin, Saber Tanha Amin, Noroozi Masoud, Arabi Hossein

СтатьяПеревод в очереди

Аннотация

PURPOSE: This preliminary study evaluates the feasibility and clinical value of sparse-view acquisition in 99m Tc-prostate specific membrane antigen (PSMA) single photon emission computed tomography (SPECT) prostate imaging. This study also compares the performance of traditional Gaussian filtering vs. an edge-preserving nonlocal means (NLM) filter in the sparse-view SPECT approach.

METHODS

Ten patients with biopsy-proven prostate cancer (Gleason 4-10) underwent full-angle acquisitions (60 views), which were decimated to 30, 15, and 10 views. Images were reconstructed with ordered-subsets expectation maximization (9 iterations, 5 subsets) and postfiltered with a Gaussian kernel or NLM. Quantitative performance metrics included mean absolute percentage error (MAPE), normalized root mean square error (NRMSE), peak signal-to-noise ratio (PSNR), and normalized bias (NB). Two nuclear medicine physicians (10-12 years' experience) provided blinded visual assessments.

RESULTS

Halving the views to 30 preserved diagnostic accuracy (MAPE_ROI1 ≤ 7%). Reducing to 15 views introduced sampling artifacts consistent with violation of the angular Nyquist limit, and 10 views produced unacceptable artifacts (MAPE_ROI1 > 50%). For 30-view reconstructions, NLM outperformed Gaussian, improving NRMSE by up to 39.3%, PSNR by 4.5%, and NB by 18.55%. Expert readers confirmed these trends, with high interobserver agreement (intraclass correlation coefficient = 0.83) for 30 views.

CONCLUSION

Sparse-view 99m Tc-PSMA SPECT with 30 views appears feasible for routine and emergency prostate imaging in this setting. Reconstructions from 15 views showed aliasing from angular undersampling and are not recommended without anti-aliasing strategies and further validation. This work characterizes the added value of NLM postreconstruction filtering in PSMA-SPECT and motivates larger studies.

Для цитирования: Jamaati Sayna, Dorri Giv Masoumeh, Hong Xiaotong, Sadeghi Ramin, Saber Tanha Amin, Noroozi Masoud, Arabi Hossein. Sparse-view reconstruction and noise reduction in 99m Tc-prostate specific membrane antigen prostate imaging.. Nuclear medicine communications. 2025. DOI: 10.1097/mnm.0000000000002079.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.