MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1253/circj.cj-24-0863

Медицинская библиотека · Circulation journal : official journal of the Japanese Circulation Society · 2025

Preoperative Longitudinal Strain on Computed Tomography Is a Sensitive Marker of Patient Prognosis After Transcatheter Aortic Valve Replacement.

Matsumoto Moe, Takaoka Hiroyuki, Takahashi Manami, Ota Joji, Noguchi Yoshitada, Okita Shogo, Nishikawa Yusei, Yoshida Kazuki, Suzuki Katsuya, Yaginuma Hiroaki, Aoki Shuhei, Goto Hiroki, Yashima Satomi, Kinoshita Makiko, Sasaki Haruka, Suzuki-Eguchi Noriko, Kitahara Hideki, Matsuura Kaoru, Matsumiya Goro, Kobayashi Yoshio

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

This study evaluated the utility of myocardial strain analysis on computed tomography (CT) using state-of-the-art image analysis software to predict the prognosis of patients who underwent transcatheter aortic valve replacement (TAVR).

METHODS AND

RESULTS

We included 126 patients with severe aortic valve stenosis (AS) who underwent preoperative CT. Major adverse cardiovascular events (MACE) were defined as a composite of cardiac death (including unknown death based on medical records), hospitalization due to heart failure, and fatal arrhythmia. Twenty-four (19%) patients experienced MACE. Global longitudinal strain (GLS), circumferential strain (GCS), radial strain (GRS) of the left ventricular (LV) myocardium (LVM), LV ejection fraction on CT, and the percentage of patients administered aspirin or statins was significantly lower among patients with than without MACE (all P<0.05). The percentage of patients with AF, a history of congestive heart failure, and tolvaptan or oral anticoagulants administration was significantly higher among patients with than without MACE (all P<0.05). In multivariate survival analysis using a Cox proportional hazard model, LV-GLS ≥-9.92% on CT (hazard ratio [HR] 4.45; 95% confidence interval [CI] 1.89-10.48; P=0.0007) and aspirin (HR 0.27; 95% CI 0.10-0.70; P=0.0074) or statin (HR 0.33; 95% CI 0.13-0.84; P=0.02) administration were significant predictors of prognosis after TAVR.

CONCLUSIONS

Our findings indicate that LV-GLS on CT is a sensitive predictor of prognosis after TAVR.

Для цитирования: Matsumoto Moe, Takaoka Hiroyuki, Takahashi Manami, Ota Joji, Noguchi Yoshitada, Okita Shogo, Nishikawa Yusei, Yoshida Kazuki, Suzuki Katsuya, Yaginuma Hiroaki, Aoki Shuhei, Goto Hiroki, Yashima Satomi, Kinoshita Makiko, Sasaki Haruka, Suzuki-Eguchi Noriko, Kitahara Hideki, Matsuura Kaoru, Matsumiya Goro, Kobayashi Yoshio. Preoperative Longitudinal Strain on Computed Tomography Is a Sensitive Marker of Patient Prognosis After Transcatheter Aortic Valve Replacement.. Circulation journal : official journal of the Japanese Circulation Society. 2025. DOI: 10.1253/circj.cj-24-0863.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.