BACKGROUND

Gynecare Prolift has been successfully used for pelvic floor repair with favorable objective and subjective outcomes. There have been, however, increasing reports of significant rates of postoperative dyspareunia and impairment of sexual function.

MATERIALS AND

METHODS

We are presenting two cases of post Prolift dyspareunia. The patients underwent several vaginal revisions with excision of the apical bands. However, they returned soon with the same complaint. Ultimately, laparoscopic excision of the apical mesh was performed.

RESULTS

Patients reported significant improvement in their intercourse pain after the procedure.

CONCLUSION

Our experience shows that new onset dyspareunia is primarily caused by the apical component of the Prolift system with deep penetration pain reproduced by pressure on the fixed nondistensible apex. This problem can be treated laparoscopically with excision of the apical mesh.

Для цитирования: Walid M Sami, Heaton Richard L. Laparoscopic apical mesh excision for deep dyspareunia caused by mesh banding in the vaginal apex.. Archives of gynecology and obstetrics. 2009. DOI: 10.1007/s00404-008-0911-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.