MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1078-5884(96)80179-1

Медицинская библиотека · European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery · 1996

The effect of a surveillance programme on the patency of synthetic infrainguinal bypass grafts.

Dunlop P, Sayers R D, Naylor A R, Bell P R, London N J

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Vein graft surveillance is widely acknowledged to be of benefit in improving graft patency at least in the first year after arterial bypass surgery. The aim of this study was to examine the effect of a surveillance programme on the patency of synthetic infrainguinal bypass grafts.

DESIGN

A prospective study of 69 consecutive prosthetic bypass grafts was undertaken over a 3 year period.

METHODS

Patients were seen at 3 monthly intervals after surgery and underwent measurement of ankle brachial pressure indices and a colour Duplex scan of the graft.

RESULTS

The surveillance programme was able to detect treatable lesions in five grafts and in the run-off vessels of two other grafts prior to occlusion. However 14 grafts failed after the first 30 days, 12 of which were not predicted by the surveillance programme.

CONCLUSIONS

Surveillance appears to be of limited benefit in the maintenance of patency of synthetic infrainguinal bypass grafts.

Для цитирования: Dunlop P, Sayers R D, Naylor A R, Bell P R, London N J. The effect of a surveillance programme on the patency of synthetic infrainguinal bypass grafts.. European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery. 1996. DOI: 10.1016/s1078-5884(96)80179-1.