MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-024-62607-w

Медицинская библиотека · Scientific reports · 2024

Evaluation of short and mid-term clinical outcomes in patients with aortic coarctation treated with self-expandable stents.

Mohammadzadeh Shabestari Mahmoud, Eshraghi Ali, Hakim Attar Farnaz, Ghaderi Fereshteh, Poorzand Hoorak, Mohammadzadeh Shabestari Amir Hossein, Alizadeh Behzad, Morovatdar Negar, Shahri Bahram, Alimi Hedieh, Tayyebi Mohammad, Gholoobi Arash, Askari Vahid Reza, Garivani Yousef Ali, Mohammadzadeh Shabestari Mohammad, Baradaran Rahimi Vafa

СтатьяПеревод в очереди

Аннотация

The present study aimed to evaluate the outcomes of percutaneous treatment of aortic coarctation using self-expandable uncovered Nitinol stents. We conducted a retrospective clinical data review of all patients with aortic coarctation and treated with self-expandable uncovered Nitinol stents at our institution between 2009 and 2019. The gradient pressure across the coarctation site was measured using aortography. Follow-up echocardiography and computed tomography angiography were performed to assess possible stent complications. A total of 127 stents were successfully implanted in 125 patients (64.8% males) with a mean age of 35.36 ± 11.9 years. The gradient across the coarctation site decreased significantly from 67.48 ± 14.79 to 5.04 ± 3.01 mmHg (P < 0.001) after self-expandable stent implantation. Systolic blood pressure (SBP) decreased significantly from 175.53 ± 15.99 to 147.22 ± 12.83 mmHg (P < 0.001) after self-expandable stenting. There were no major technical or clinical complications, including balloon rupture, aneurysmal formation, infection, secondary stent migration, thrombosis, death during the procedure, and in-hospital mortality. On a mean follow-up of 48 ± 23.6 months (12-120 months), the gradient [from 59.43 ± 15.42 to 3.72 ± 1.38 mmHg (P < 0.001)] and SBP [from 175.53 ± 15.99 to 127.99 ± 7.82 mmHg (P < 0.001)] decreased significantly. There was no mortality, aneurysmal formation in the stent site, dislocation, or aortic re-stenosis requiring intervention during mid-term follow-up. Treatment of aortic coarctation using a self-expandable uncovered nitinol stent is safe and effective with promising mid-term outcomes.

Для цитирования: Mohammadzadeh Shabestari Mahmoud, Eshraghi Ali, Hakim Attar Farnaz, Ghaderi Fereshteh, Poorzand Hoorak, Mohammadzadeh Shabestari Amir Hossein, Alizadeh Behzad, Morovatdar Negar, Shahri Bahram, Alimi Hedieh, Tayyebi Mohammad, Gholoobi Arash, Askari Vahid Reza, Garivani Yousef Ali, Mohammadzadeh Shabestari Mohammad, Baradaran Rahimi Vafa. Evaluation of short and mid-term clinical outcomes in patients with aortic coarctation treated with self-expandable stents.. Scientific reports. 2024. DOI: 10.1038/s41598-024-62607-w.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.