m+Medelevator.RU
← Поиск публикаций
Child's nervous system : ChNS : official journal of the International Society for Pediatric Neurosurgery · 1995

Non-invasive ICP monitoring in infants: the Rotterdam Teletransducer revisited.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Peters R J, Hanlo P W, Gooskens R H, Braun K P, Tulleken C A, Willemse J

Аннотация

Measurement of intracranial pressure (ICP) is important in patients at risk of raised ICP, as in hydrocephalus. Ideally, it should be non-invasive, thus avoiding the risk of infection and other complications: Such is provided by measurement of ICP through the anterior fontanelle. There are several methods of measuring anterior fontanelle pressure (AFP); those most frequently used are based on the applanation principle. An evaluation of AFP measurement devices resulted in the choice of the Rotterdam Teletransducer (RTT) to be used in our study of children with hydrocephalus. The literature contains little information on the accuracy or validation of the AFP measurements using the RTT. Therefore, the physical qualities of the RTT were reassessed, using a specially developed calibration device. The results of this study demonstrate that membrane temperature does not have any effect on the measured pressure. The thermal stabilization time of the RTT was found to be 3 h after switching on. Insufficient thermal stabilization results in a pressure underestimation of up to 3 mmHg. Furthermore, a maximum inaccuracy of 2.6 mmHg, after calibration and readjustment of the transducer, was calculated. Validation of the equipment was achieved by simultaneous AFP/ICP measurements in hydrocephalic patients showing high correlations (r = 0.96-0.98). The discussion suggests a measurement protocol as a means of increasing the reliability of RTT measurements.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты