DOI 10.1118/1.4747266

Медицинская библиотека · Medical physics · 2012

Differences in predicted and actually absorbed doses in peptide receptor radionuclide therapy.

Kletting Peter, Muller Berthold, Erentok Bahar, Schmaljohann Jorn, Behrendt Florian F, Reske Sven N, Mottaghy Felix M, Glatting Gerhard

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: An important assumption in dosimetry prior to radionuclide therapy is the equivalence of pretherapeutic and therapeutic biodistribution. In this study the authors investigate if this assumption is justified in sst2-receptor targeting peptide therapy, as unequal amounts of peptide and different peptides for pretherapeutic measurements and therapy are commonly used.

METHODS

Physiologically based pharmacokinetic models were developed. Gamma camera and serum measurements of ten patients with metastasizing neuroendocrine tumors were conducted using (111)In-DTPAOC. The most suitable model was selected using the corrected Akaike information criterion. Based on that model and the estimated individual parameters, predicted and measured (90)Y-DOTATATE excretions during therapy were compared. The residence times for the pretherapeutic (measured) and therapeutic scenarios (simulated) were calculated.

RESULTS

Predicted and measured therapeutic excretion differed in three patients by 10%, 31%, and 7%. The measured pretherapeutic and therapeutic excretion differed by 53%, 56%, and 52%. The simulated therapeutic residence times of kidney and tumor were 3.1 ± 0.6 and 2.5 ± 1.2 fold higher than the measured pretherapeutic ones.

CONCLUSIONS

To avoid the introduction of unnecessary inaccuracy in dosimetry, using the same substance along with the same amount for pretherapeutic measurements and therapy is recommended.

Для цитирования: Kletting Peter, Muller Berthold, Erentok Bahar, Schmaljohann Jorn, Behrendt Florian F, Reske Sven N, Mottaghy Felix M, Glatting Gerhard. Differences in predicted and actually absorbed doses in peptide receptor radionuclide therapy.. Medical physics. 2012. DOI: 10.1118/1.4747266.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.