MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10278-026-01996-y

Медицинская библиотека · Journal of imaging informatics in medicine · 2026

Attention-Based Point Cloud Completion for CT-Equivalent Kidney Volumetry from Tracked Freehand Ultrasound.

Ge Sikai, Ma Wuwei, Tang Hao, Wu Menglin, Wang Shanshan, Wu Junwei, Ma Fei, Shang Xuejun

СтатьяПеревод в очереди

Аннотация

Kidney volume measurement is critical for managing polycystic kidney disease and monitoring transplants, but computed tomography involves radiation and conventional ultrasound has 20-30% error. This study validates tracked freehand ultrasound with attention-based point cloud completion for kidney volumetry, with the primary objective of determining equivalence to computed tomography within a ± 2% margin. Sixty healthy volunteers (30 male, 30 female; mean age 44 years; enrolled March-August 2024; 120 kidneys) undergoing routine health examination computed tomography underwent electromagnetic-tracked ultrasound using three standardized scanning maneuvers and same-day computed tomography. Sparse point clouds from ultrasound were completed using an attention-based transformer network (PointAttN) and four benchmark architectures. Volumes were compared against computed tomography using equivalence testing on per-kidney relative differences within a ± 2% margin. Tracked freehand ultrasound achieved mean absolute error of 3.94 mL (3.0% relative error) in multiaxis merged mode and passed statistical equivalence testing (TOST: p1 < 0.001, p2 = 0.043). Single-axis scanning failed equivalence testing across all methods with 2-4 times higher errors. Tracked freehand ultrasound with attention-based point cloud completion demonstrates kidney volume measurement accuracy approaching CT-level precision in healthy volunteers, passing formal statistical equivalence testing within a 2% margin. These algorithm-based results require validation in clinical populations with renal pathology and comparison with radiologist assessment before broader deployment. Multiaxis scanning is necessary for clinical accuracy.

Для цитирования: Ge Sikai, Ma Wuwei, Tang Hao, Wu Menglin, Wang Shanshan, Wu Junwei, Ma Fei, Shang Xuejun. Attention-Based Point Cloud Completion for CT-Equivalent Kidney Volumetry from Tracked Freehand Ultrasound.. Journal of imaging informatics in medicine. 2026. DOI: 10.1007/s10278-026-01996-y.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.