MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajog.2008.07.031

Медицинская библиотека · American journal of obstetrics and gynecology · 2008

Does the Prolift system cause dyspareunia?

Lowman Joye K, Jones Leticia A, Woodman Patrick J, Hale Douglass S

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study was to determine the de novo dyspareunia rate with the Prolift procedure.

STUDY

DESIGN

All Prolift cases performed between August 2005 and August 2007 were evaluated. The rate of de novo dyspareunia was calculated by chart review. Type and degree of dyspareunia were assessed by self-administered questionnaire. Demographics, use of hormone therapy, failure rate, and willingness to have the surgery again were summarized using descriptive statistics.

RESULTS

The rate of de novo dyspareunia was 16.7%. Over 75% of patients with de novo dyspareunia described the pain as mild or moderate. Most described dyspareunia with insertion. Eighty-three percent of respondents with de novo dyspareunia would have the procedure done again.

CONCLUSION

The Prolift is associated with a 17% de novo dyspareunia rate. Despite this, most would have the surgery done again.

Для цитирования: Lowman Joye K, Jones Leticia A, Woodman Patrick J, Hale Douglass S. Does the Prolift system cause dyspareunia?. American journal of obstetrics and gynecology. 2008. DOI: 10.1016/j.ajog.2008.07.031.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.