MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.24956

Медицинская библиотека · Magnetic resonance in medicine · 2013

Imaging neurodegeneration in the mouse hippocampus after neonatal hypoxia-ischemia using oscillating gradient diffusion MRI.

Aggarwal Manisha, Burnsed Jennifer, Martin Lee J, Northington Frances J, Zhang Jiangyang

СтатьяПоддержка NIH: внешняя программаПеревод в очереди

Аннотация

PURPOSE: To investigate if frequency-dependent contrasts using oscillating gradient diffusion MRI (dMRI) can detect hypoxia-ischemia (HI) -induced neurodegeneration in the neonatal mouse hippocampus.

METHODS

Pulsed- and oscillating-gradient dMR images (at 50, 100, and 150 Hz) were acquired from postmortem fixed brains of mice exposed to neonatal HI using the Rice-Vanucci model. MRI data were acquired at 1, 4, and 8 days following HI, and compared with histological data from the same mice for in situ histological validation of the MRI findings.

RESULTS

The rate of change of apparent diffusion coefficient with gradient frequency (Δf ADC) revealed unique layer-specific contrasts in the neonatal mouse hippocampus. Δf ADC measurements were found to show a significant decrease in response to neonatal HI injury, in the pyramidal (Py) and granule (GrDG) cell layers compared with contralateral regions. The areas of reduced intensity in the Δf ADC maps corresponded to regional neurodegeneration seen with H&E and Fluoro-Jade C stainings, indicating that alterations in Δf ADC contrasts are sensitive to early microstructural changes due to HI-induced neurodegeneration in the studied regions.

CONCLUSION

The findings show that the frequency-dependence of ADC measurements with oscillating-gradient dMRI can provide a sensitive contrast to detect HI-induced neurodegeneration in neuronal layers of the neonatal mouse hippocampus.

Для цитирования: Aggarwal Manisha, Burnsed Jennifer, Martin Lee J, Northington Frances J, Zhang Jiangyang. Imaging neurodegeneration in the mouse hippocampus after neonatal hypoxia-ischemia using oscillating gradient diffusion MRI.. Magnetic resonance in medicine. 2013. DOI: 10.1002/mrm.24956.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.