MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/micr.20894

Медицинская библиотека · Microsurgery · 2011

An in vivo engineered nerve conduit--fabrication and experimental study in rats.

Penna Vincenzo, Munder Beatrix, Stark G-Bjoern, Lang Eva M

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Several types of nerve conduits have been used for peripheral nerve gap bridging. This study investigated the in vivo engineering of a biological nerve conduit and its suitability for nerve gap bridging.

MATERIAL AND

METHODS

A 19-mm long polyvinyl chloride (PVC) tube was implanted parallely to the sciatic nerve. After implantation, a connective tissue cover developed around the PVC-tube, the so-called biogenic conduit. Histological cross-sections were performed after 1, 2, 3, and 4 weeks. Wall thicknesses were measured and all vessels per cross-section were counted. The biogenic conduit filled with fibrin was used to bridge a 15-mm long nerve gap in the sciatic lesion model of the rat (n = 8). The results of nerve repair with the conduit were compared to the autologous nerve graft (n = 8). Sciatic functional index (SFI), nerve area, axon count, myelination index, and ratio of total myelinated fiber area/nerve area (N-ratio) were analyzed after 4 weeks.

RESULTS

The wall thickness of biogenic conduits increased over the 4 weeks implantation time. Biogenic conduits revealed highest number of vessels per cross-section after 4 weeks. The results of SFI analysis did not show significant difference between the repairs with biogenic conduit and autologous nerve graft. Nerve area and axon count in the biogenic conduit group were significantly lower than in the autologous nerve group (P < 0.001). The biogenic conduit group showed significant higher myelination values, but lower N-ratio when compared to the nerve graft group (P < 0.001).

CONCLUSIONS

The in vivo engineered conduits allow nerve gap bridging of 15 mm. However, quality of regeneration after 4 weeks observation time is not comparable to autologous nerve grafts. Whether biogenic conduits might be a suitable alternative to artificial and biological conduits for gap bridging will have to be evaluated in further studies.

Для цитирования: Penna Vincenzo, Munder Beatrix, Stark G-Bjoern, Lang Eva M. An in vivo engineered nerve conduit--fabrication and experimental study in rats.. Microsurgery. 2011. DOI: 10.1002/micr.20894.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.