The journal of obstetrics and gynaecology research · 2023
Assessment of maternal serum SERPINC1, E-selectin, P-selectin, and RBP4 levels in pregnancies with early- and late-onset preeclampsia.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Palalıoğlu Rabia Merve, Erbiyik Halil Ibrahim
Аннотация
INTRODUCTION: To investigate whether the SERPINC1, E-selectin, P-selectin, and RBP4 levels in first trimester maternal serum was associated with the presence of preeclampsia (PE).
METHODS: This cross-sectional study was conducted on 26 women with early-onset preeclampsia (EO-PE), 27 women with late-onset preeclampsia (LO-PE), and 27 women with uncomplicated pregnancies. Levels of serum SERPINC1, E-selectin, P-selectin, and RBP4 were measured with the use of an enzyme-linked immunosorbent assay (ELISA) kit.
RESULTS: E-Selectin levels in patients with EO-PE were higher than those with LO-PE and control patients (pE-L = 0.025; pE-C = 0.000; p < 0.05). There was no significant intergroup difference in terms of P-selectin and RBP4 levels (p > 0.05). SERPINC1 levels were lower in the patients in the with EO-PE group than in those in the LO-PE and the control groups (pE-L = 0.000; pE-C = 0.000; p < 0.05). In the PE group, there was a negative, moderate (41.7%) correlation between E-selectin level and SERPINC1 (p = 0.002; p < 0.05). The receiver operating characteristic (ROC) curve showed that the best cut-off values for E-selectin were 23.14 ng/ml > with 100% sensitivity and 100% specificity. The ROC curve showed that the best cut-off values for SERPINC1 were ≤87.76 ng/ml with 98.1% sensitivity and 96.3% specificity.
DISCUSSION: Of the endothelial damage parameters, E-selectin and SERPINC1 are especially associated with EO-PE. Furthermore, they can be used as potential early diagnosis markers in the prediction of PE.
METHODS: This cross-sectional study was conducted on 26 women with early-onset preeclampsia (EO-PE), 27 women with late-onset preeclampsia (LO-PE), and 27 women with uncomplicated pregnancies. Levels of serum SERPINC1, E-selectin, P-selectin, and RBP4 were measured with the use of an enzyme-linked immunosorbent assay (ELISA) kit.
RESULTS: E-Selectin levels in patients with EO-PE were higher than those with LO-PE and control patients (pE-L = 0.025; pE-C = 0.000; p < 0.05). There was no significant intergroup difference in terms of P-selectin and RBP4 levels (p > 0.05). SERPINC1 levels were lower in the patients in the with EO-PE group than in those in the LO-PE and the control groups (pE-L = 0.000; pE-C = 0.000; p < 0.05). In the PE group, there was a negative, moderate (41.7%) correlation between E-selectin level and SERPINC1 (p = 0.002; p < 0.05). The receiver operating characteristic (ROC) curve showed that the best cut-off values for E-selectin were 23.14 ng/ml > with 100% sensitivity and 100% specificity. The ROC curve showed that the best cut-off values for SERPINC1 were ≤87.76 ng/ml with 98.1% sensitivity and 96.3% specificity.
DISCUSSION: Of the endothelial damage parameters, E-selectin and SERPINC1 are especially associated with EO-PE. Furthermore, they can be used as potential early diagnosis markers in the prediction of PE.