MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1526602814565776

Медицинская библиотека · Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists · 2015

Radiofrequency in situ fenestration for aortic arch vessels during thoracic endovascular repair.

Tse Leonard W, Lindsay Thomas F, Roche-Nagle Graham, Oreopoulos George D, Ouzounian Maral, Tan Kong Teng

СтатьяПеревод в очереди

Аннотация

PURPOSE: To report the first clinical application of a novel technique using radiofrequency puncture to create retrograde in situ fenestrations during thoracic endovascular aortic repair (TEVAR).

METHODS

Between June 2011 and December 2013, 40 TEVAR procedures were performed in our facility, including 10 cases in which in situ fenestration was planned. Two thoracic stent-graft models were deployed: the Valiant (n=5) and the Zenith TX2 (n=5). A 0.035-inch PowerWire radiofrequency guidewire delivered from a brachial approach was used to fenestrate the grafts covering a left subclavian artery (LSA) in 9 cases and a left common carotid artery in one. The fenestrations were serially dilated to 6 mm, and self-expanding Advanta V12 covered stents were positioned in the target arteries.

RESULTS

Technical success was achieved in 6 of the 10 planned cases. Of the remaining 4 cases, stent-grafts were deployed in zone 3 in 2 cases (one received a chimney to the LSA). Another stent-graft was deployed in zone 2 without endoleak after fenestration was abandoned (the LSA had good filling via the vertebral artery). In the last case, the fenestration was unsuccessful in double-layered (proximal extension overlap) stent-grafts; a carotid-axillary bypass was required. There were no fenestration-related complications, but overall surgical complications included a case of paraparesis that resolved following spinal drainage and a death from a preexisting aortoesophageal fistula. There were no postoperative strokes. All fenestrations remained patent, and there were no endoleaks at a mean 12-month follow-up (range 1-33).

CONCLUSION

Radiofrequency puncture is a viable alternative to needle or laser punctures for in situ fenestration during TEVAR. Early clinical results suggest technical feasibility and acceptable early outcomes.

Для цитирования: Tse Leonard W, Lindsay Thomas F, Roche-Nagle Graham, Oreopoulos George D, Ouzounian Maral, Tan Kong Teng. Radiofrequency in situ fenestration for aortic arch vessels during thoracic endovascular repair.. Journal of endovascular therapy : an official journal of the International Society of Endovascular Specialists. 2015. DOI: 10.1177/1526602814565776.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.