An Implantable System Design Based on Neuromorphic Memristor for Post-Craniotomy Intracranial Pressure Monitoring.

Wu Teng, Wang Kun, Sun Bai, Cao Zelin, Gu Junxiang, Liang Meirou, Le Yifan, Li Fan, Wang Jian, Xiao Yifan, Wang Mengna, Fu Longhui, Gao Kaikai, Wang Haoyuan, Ma Hui, Du Xincheng, Liu Jiajun, Qu Jianqiang, Liu Chang, Zhou Guangdong, Shao Jinyou, Yan Xianxia

СтатьяПеревод в очереди

Аннотация

Craniotomy, a complex neurosurgical intervention, carries significant risks of postoperative complications including intracerebral hemorrhage (ICH) and cerebral edema, causing elevated intracranial pressure (ICP) and life-threatening cerebral herniation. However, the current ventricular catheter ICP monitoring technologies pose risks of infection and hemorrhage, and restrict patient mobility during medical procedures. There is thus an urgent need to develop ICP monitoring technologies that simultaneously achieve sensitivity, safety, and portability. Memristors, with their integrated memory, sensing, and neuromorphic computing capabilities, offer a promising solution to traditional monitoring bottlenecks. In this work, we innovatively developed an Ag/WO3/MnO2/FTO-structured memristor and validated its pressure signal encoding capability in vitro via integration with a pressure sensor. A collagenase-induced ICH animal model was established to simulate postcraniotomy intracranial hypertension. Following model induction, the sensor-memristor system was implanted for intracranial pressure signal acquisition and encoding. The encoded signals were prospectively processed through a memristor-based logic circuit for noise reduction, and analyzed and classified via a memristive neural network. This study demonstrates the potential of implantable memristor-sensor system for postcraniotomy ICP monitoring and underscores its role in enhancing neurosurgical care, which also provides innovative insights for designing efficient, real-time, and low-power consumption implantable pressure monitoring devices for medical health monitoring.

Для цитирования: Wu Teng, Wang Kun, Sun Bai, Cao Zelin, Gu Junxiang, Liang Meirou, Le Yifan, Li Fan, Wang Jian, Xiao Yifan, Wang Mengna, Fu Longhui, Gao Kaikai, Wang Haoyuan, Ma Hui, Du Xincheng, Liu Jiajun, Qu Jianqiang, Liu Chang, Zhou Guangdong, Shao Jinyou, Yan Xianxia. An Implantable System Design Based on Neuromorphic Memristor for Post-Craniotomy Intracranial Pressure Monitoring.. ACS applied materials & interfaces. 2025. DOI: 10.1021/acsami.5c14010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.