DOI 10.1016/j.foodchem.2017.12.079

Медицинская библиотека · Food chemistry · 2018

Development of direct competitive biomimetic immunosorbent assay based on quantum dot label for determination of trichlorfon residues in vegetables.

Liu Qiurui, Jiang Mingdi, Ju Zeliang, Qiao Xuguang, Xu Zhixiang

СтатьяПеревод в очереди

Аннотация

A direct competitive biomimetic immunosorbent assay method based on molecularly imprinted polymer was developed for the determination of trichlorfon. A CdSe/ZnS quantum dot label was used as the marker. The hydrophilic imprinted film was synthesized directly on the surface of a 96-well plate, and characterized by Fourier-transform infrared spectroscopy and thermo-gravimetric analyses. The method exhibited high stability, selectivity, and sensitivity. Under optimal conditions, the limits of detection and sensitivity of the biomimetic immunosorbent assay method were 9.0 μg L-1 and 5.0 mg L-1 (0.1 mg kg-1 and 62.5 mg kg-1 for vegetable sample), respectively. Low cross-reactivity values of 19.2% and 15.6% were obtained for the structural analogues. Spinach and rape samples spiked with trichlorfon were extracted and determined by this method with recoveries ranging from 83.6% to 91.1%. The method was applied for the detection of trichlorfon residues in leek and cucumber samples, and results correlated well with those obtained using GC.

Для цитирования: Liu Qiurui, Jiang Mingdi, Ju Zeliang, Qiao Xuguang, Xu Zhixiang. Development of direct competitive biomimetic immunosorbent assay based on quantum dot label for determination of trichlorfon residues in vegetables.. Food chemistry. 2018. DOI: 10.1016/j.foodchem.2017.12.079.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.