MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5152/dir.2019.18358

Медицинская библиотека · Diagnostic and interventional radiology (Ankara, Turkey) · 2019

Diffusion-weighted imaging of placenta in intrauterine growth restriction with worsening Doppler US findings.

Görkem Süreyya Burcu, Coşkun Abdulhakim, Eşlik Murside, Kütük Mehmet Serdar, Öztürk Ahmet

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: We aimed to compare the placental diffusion difference between intrauterine growth restriction (IUGR) patients with worsening Doppler ultrasonography (US) findings and control group with normal Doppler US findings by using diffusion-weighted imaging (DWI).

METHODS

We performed a prospective study to compare the placental diffusion difference in 63 patients (gestational week, 28-34 weeks), including 50 IUGR patients (mean gestational week, 30 weeks 3 days ±16.2 days) with worsening Doppler US findings and 13 patients with normal Doppler US findings (mean gestational week, 29 weeks 4 days ±12.3 days) by using DWI (b value, 0-1000 s/mm2). We classified IUGR patients into three groups according to the reference values of the umbilical artery pulsatility index (PI) chart. Placenta apparent diffusion coefficient (ADC) calculations were performed by freehand drawn regions-of-interest (ROIs) (min, 8.04 cm2; max, 200 cm2).

RESULTS

Placental ADC values in IUGR patients (mean, 1.624±0.181 ×10-³ mm²/s; range, 1.35-1.96 ×10-3 mm2/s) were significantly reduced compared with the control group (mean, 1.827±0.191 ×10-³ mm²/s; range, 1.35-2.84 ×10-3 mm2/s) (P = 0.001). For adjusted ROI area calculation, ADC values were significantly lower in groups 3, 2 and 1, respectively, compared with the control group (P < 0.05); and there was no significant difference between groups 1 and 2 (P > 0.05). Preeclampsia significantly reduced the placental diffusion compared with patients without preeclampsia (P = 0.003). Gestational aging did not significantly affect ADC values in control patients (r=0.08, P = 0.561). The sensitivity, specificity, negative and positive predictive values of ADC to detect IUGR were 72%, 84.6%, 44%, and 94.7% with a cutoff value of 1.727 ×10-3 mm2/s, respectively.

CONCLUSION

The diagnostic estimation of placental ADC values to predict the severity of IUGR is comparable to that of umbilical artery PI. Considering that at the very early onset of IUGR, placental diffusion diminishes, ADC as a marker for IUGR in lieu of umbilical artery PI has the potential to determine the threshold for decreased placental diffusion. Therefore, DWI should be added to routine fetal MRI to show diffusion changes in placenta.

Для цитирования: Görkem Süreyya Burcu, Coşkun Abdulhakim, Eşlik Murside, Kütük Mehmet Serdar, Öztürk Ahmet. Diffusion-weighted imaging of placenta in intrauterine growth restriction with worsening Doppler US findings.. Diagnostic and interventional radiology (Ankara, Turkey). 2019. DOI: 10.5152/dir.2019.18358.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.