MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/md.0000000000016449

Медицинская библиотека · Medicine · 2019

Diagnostic accuracy of cervical elastography in predicting preterm delivery: A systematic review and meta-analysis.

Wang Bo, Zhang Yong, Chen Shuangshuang, Xiang Xiaowei, Wen Juan, Yi Mei, He Baiyun, Hu Bing

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

The aim of the study was to evaluate the diagnostic accuracy of cervical elastography in predicting preterm delivery (PTD).

METHODS

We searched the PubMed, EMBASE, and Cochrane databases to identify relevant studies that applied ultrasound (US) elastography to assess cervical stiffness and predict PTD. All the studies were published before December 11, 2018, and only studies published in English were collected. The cervical length (CL) was considered a comparator, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was applied to assess the quality of the included studies. Summary receiver operating characteristic (SROC) modeling was performed to evaluate the diagnostic performance of cervical elastography in predicting PTD. Subgroup analyses were also performed.

RESULTS

Seven studies, including 1488 pregnant women, were included in this meta-analysis. Cervical elastography showed a summary sensitivity of 0.84 [95% confidence interval (CI): 0.68, 0.93], a specificity of 0.82 (95% CI: 0.63, 0.93), a diagnostic odds ratio of 25 (95% CI: 7, 93), and an area under the curve (AUC) of SROC of 0.90 (95% CI: 0.87-0.93). CL measurement showed that the AUC of SROC was 0.60 (95% CI: 0.56-0.64). The results of subgroup analysis showed that the summary sensitivity and specificity were different in the QUADAS-2 score subgroups.

CONCLUSION

Cervical elastography is a promising and reliable method to predict PTD. Cervical elastography showed better diagnostic performance to predict PTD than CL measurement.

Для цитирования: Wang Bo, Zhang Yong, Chen Shuangshuang, Xiang Xiaowei, Wen Juan, Yi Mei, He Baiyun, Hu Bing. Diagnostic accuracy of cervical elastography in predicting preterm delivery: A systematic review and meta-analysis.. Medicine. 2019. DOI: 10.1097/md.0000000000016449.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.