Operative management of intrauterine device complications: a case series report.

Turok David K, Gurtcheff Shawn E, Gibson Keri, Handley Erin, Simonsen Sara, Murphy Patricia A

СтатьяПеревод в очереди

Аннотация

BACKGROUND

There is limited information about the number of intrauterine device (IUD) users requiring operative intervention for device-related complications. This is an evaluation of cases requiring in-hospital operative intervention for IUD perforations, removals and pregnancy-related complications.

STUDY

DESIGN

Large retrospective case series of patients who received operative management of IUD complications.

RESULTS

Charts of patients from 15 hospitals in two health care systems from 2000 to 2007 were reviewed and outcomes of 276 women are reported. There were 95 operative IUD removals for perforations (including 60 levonorgestrel-releasing intrauterine systems), 157 operative procedures for inability to remove an IUD in the office, and 42 pregnancy-related complications that were managed in the operating room. Ectopic pregnancy was the most common diagnosis among pregnant women (23 of 42 pregnant women, 54.8%).

CONCLUSION

The majority of operative procedures were performed for intrauterine IUDs, most of which were appropriately positioned IUDs with missing or short strings. In-office techniques for obtaining analgesia and dilation as well as appropriate devices for removal of T-shaped IUDs should make this practice rare.

Для цитирования: Turok David K, Gurtcheff Shawn E, Gibson Keri, Handley Erin, Simonsen Sara, Murphy Patricia A. Operative management of intrauterine device complications: a case series report.. Contraception. 2010. DOI: 10.1016/j.contraception.2010.04.152.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.