MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5144/0256-4947.2014.494

Медицинская библиотека · Annals of Saudi medicine · 2014

The short- and long-term effect of Blalock-Taussig shunt size on the outcome after first palliative surgery for cyanotic heart diseases.

Elella Raja Abou, Umereta Neil, Alabari Ismail, Al Ahmadi Mamdouh, Al Wadai Abdullah

СтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

The Blalock-Taussig (BT) shunt is regarded a safe and effective means increasing pulmonary blood flow for cyanotic heart conditions. The evaluation of shunt size for postoperative hemodynamics and until second-stage palliation remains difficult. Our objective is to compare the effect of different shunt sizes on short- and long-term outcomes after a BT shunt surgery.

DESIGN AND SETTINGS: This is a retrospective review in a tertiary care hospital.

PATIENTS: The records of all patients with a modified BT shunt between January 2007 and January 2010 were reviewed.

METHODS

Patients were divided into 2 groups: Group A with a BT shunt of 3.5 mm and Group B with a BT shunt of 4 mm, and their body weight was less than 4 kg. Groups were compared for the short-term outcome, which includes: intensive care unit course, intensive care unit (ICU) and hospital stay, mortality during the same admission, and the size of branch pulmonary arteries (PAs) before second surgery.

RESULTS

A total of 29 (42%) patients were in Group A and 40 (58%) in Group B. There was no significant difference in the mean weight between both groups; P value .06. There was no significant difference between the 2 groups in regard to diastolic blood pressure and lactate levels by the end of the first 48 hours after surgery. Group A required longer duration of inotropes and more days of ventilation with P value .03 and .001, respectively. The mean (standard deviation) ICU and hospital stay were 10.0 (8.9) days and 17.0 (11.4) days, respectively, for Group A and 12 (8.9) days and 15 (12.9) days, respectively, for Group B with P value .7 and P value .6, respectively. Yet Group B had a better branch PA size and required lesser intervention for branch PAs in comparison to Group A.

CONCLUSION

These data suggest that a smaller shunt size may have a trend toward higher morbidity. A bigger shunt size does not necessarily lead to stealing phenomena and its consequences, and can be performed with a low risk leading to a better growth of branch PAs.

Для цитирования: Elella Raja Abou, Umereta Neil, Alabari Ismail, Al Ahmadi Mamdouh, Al Wadai Abdullah. The short- and long-term effect of Blalock-Taussig shunt size on the outcome after first palliative surgery for cyanotic heart diseases.. Annals of Saudi medicine. 2014. DOI: 10.5144/0256-4947.2014.494.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.