BACKGROUND

The estimation of postmortem interval (PMI) is of paramount importance for the police in their investigation when arriving at the scene of a questionable death. The aim of present study is to evaluate the effect of elapsed time on cardiac Troponin-T degradation and its association with PMI in cases of death due to electrocution.

METHODS

Cardiac tissue samples were collected from medico-legal autopsies, after informed consent from the relatives. The cases included were the subjects of electrocution without any prior history of disease who died in the hospital and their exact time of death was known. The analysis involves extraction of the protein at room temperature for different time periods (∼5, 26, 50, 84, 132, 157, 180, 205 and 230 Hrs), separation by SDS-PAGE and visualization by Western blot using cTnT specific monoclonal antibodies.

RESULTS

The results specify a characteristic banding pattern amongst human cadavers (n = 5), a pseudo-linear relationship between percent cTnT degraded and the time since death (R(2) = 0.87, p = 0.0001) was observed. The area of the bands within a lane was quantified by scanning and digitizing the image using Gel Doc (Universal Hood II).

CONCLUSIONS

The post-mortem Troponin-T fragmentation observed in this study reveals a sequential, time-dependent process with the potential for use as a predictor of PMI in cases of electrocution.

Для цитирования: Kumar Sachil, Ali Wahid, Bhattacharya Sandeep, Singh Uma Shankar, Kumar Ashutosh, Verma Anoop K. The effect of elapsed time on cardiac troponin-T (cTnT) degradation and its relation to postmortem interval in cases of electrocution.. Journal of forensic and legal medicine. 2015. DOI: 10.1016/j.jflm.2015.05.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.