MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3109/13625187.2010.502583

Медицинская библиотека · The European journal of contraception & reproductive health care : the official journal of the European Society of Contraception · 2010

Hormonal contraception in women with the metabolic syndrome: a narrative review.

Verhaeghe Johan

СтатьяОбзорПеревод в очереди

Аннотация

OBJECTIVE

The metabolic syndrome (MS) is a set of five cardiovascular and metabolic risk factors: elevated waist circumference, fasting plasma glucose, triglycerides and blood pressure; and reduced HDL-cholesterol. The prevalence of the MS is rising worldwide, and is linked to two diagnoses in young women: polycystic ovary syndrome (PCOS) and gestational diabetes mellitus (GDM).

METHODS

This narrative review focuses on hormonal contraceptive choices available for women in Europe with features of the MS.

RESULTS

The levonorgestrel-intrauterine system and progestogen-only pills containing desogestrel or levonorgestrel have no significant effects on MS parameters. Combined oestrogen-progestogen methods do not appear to increase waist circumference or the incidence of glucose intolerance in women with PCOS or a history of GDM; their effect on HDL-cholesterol and triglycerides is comparable with that observed in women without the MS, while the effect on blood pressure remains inconclusive. The etonogestrel implant does not affect body weight, triglycerides and blood pressure but mildly reduces insulin sensitivity and HDL-cholesterol in healthy women. Depot medroxyprogesterone acetate increases body weight and truncal fat deposition, and lowers glucose tolerance in women with previous GDM.

CONCLUSIONS

Low-dose hormonal contraception is safe for many women with the MS, but high-dose progestogens must be avoided.

Для цитирования: Verhaeghe Johan. Hormonal contraception in women with the metabolic syndrome: a narrative review.. The European journal of contraception & reproductive health care : the official journal of the European Society of Contraception. 2010. DOI: 10.3109/13625187.2010.502583.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.