MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1039/d3an01519j

Медицинская библиотека · The Analyst · 2024

Serum-based ATR-FTIR spectroscopy combined with multivariate analysis for the diagnosis of pre-diabetes and diabetes.

Pang Weiyi, Xing Yu, Morais Camilo L M, Lao Qiufeng, Li Shengle, Qiao Zipeng, Li You, Singh Maneesh N, Barauna Valério G, Martin Francis L, Zhang Zhiyong

СтатьяПеревод в очереди

Аннотация

Diabetes mellitus (DM) is a metabolic disease with an increasing prevalence that is causing worldwide concern. The pre-diabetes stage is the only reversible stage in the patho-physiological process towards DM. Due to the limitations of traditional methods, the diagnosis and detection of DM and pre-diabetes are complicated, expensive, and time-consuming. Therefore, it would be of great benefit to develop a simple, rapid and inexpensive diagnostic test. Herein, the infrared (IR) spectra of serum samples from 111 DM patients, 111 pre-diabetes patients and 333 healthy volunteers were collected using attenuated total reflection Fourier-transform IR (ATR-FTIR) spectroscopy and this was combined with the multivariate analysis of principal component analysis linear discriminant analysis (PCA-LDA) to develop a discriminant model to verify the diagnostic potential of this approach. The study found that the accuracy of the test model established by ATR-FTIR spectroscopy combined with PCA-LDA was 97%, and the sensitivity and specificity were 100% and 100% in the control group, 94% and 98% in the pre-diabetes group, and 91% and 98% in the DM group, respectively. This indicates that this method can effectively diagnose DM and pre-diabetes, which has far-reaching clinical significance.

Для цитирования: Pang Weiyi, Xing Yu, Morais Camilo L M, Lao Qiufeng, Li Shengle, Qiao Zipeng, Li You, Singh Maneesh N, Barauna Valério G, Martin Francis L, Zhang Zhiyong. Serum-based ATR-FTIR spectroscopy combined with multivariate analysis for the diagnosis of pre-diabetes and diabetes.. The Analyst. 2024. DOI: 10.1039/d3an01519j.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.