MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1227/neu.0000000000001356

Медицинская библиотека · Operative neurosurgery (Hagerstown, Md.) · 2016

Percutaneous Lumbar Transfacet Screw Fixation: A Technique Analysis of 176 Screws in 83 Patients With Assessment of Radiographic Accuracy, Hardware Failure, and Complications.

Felbaum Daniel R, Lajthia Orgest, Syed Hasan R, Voyadzis Jean Marc

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Transfacet screw fixation can be used to supplement varying techniques of lumbar interbody fusion. The percutaneous placement of transfacet screws represents an alternative to pedicle screws for select cases, which can potentially minimize morbidity.

OBJECTIVE

To analyze our experience with respect to accuracy, hardware failure, and neurologic compromise.

METHODS

Clinical records gathered from August 2009 to January 2014 were retrospectively reviewed. We identified 83 patients who underwent placement of 176 consecutive percutaneous transfacet screws while in the prone or lateral position. Accuracy of screw placement was assessed on computed tomography (CT) by entry point and end point. Hardware failure was assessed by radiography or CT. Clinical complications were assessed during regular follow-up visits.

RESULTS

Entry point accuracy was 91.4%. Seven cases of intra-articular screw placement and 1 para-articular screw placement were detected on CT. End-point accuracy was 82.8%. There were 16 cases of pedicle breach from 1 to 3 mm on CT. There were 2 screw fractures and 1 case of a Kirschner-wire fracture that were clinically inconsequential. One patient had new nondisabling leg numbness. One patient with new radicular leg pain required removal of a screw.

CONCLUSION

The technique of percutaneous lumbar transfacet screw fixation can be performed accurately and safely with patients in the prone and lateral positions. Entry point inaccuracies were more common at rostral levels due to facet orientation. End-point inaccuracies (pedicle breaches) were more common in the intervertebral foramen where 2 clinical complications occurred.

Для цитирования: Felbaum Daniel R, Lajthia Orgest, Syed Hasan R, Voyadzis Jean Marc. Percutaneous Lumbar Transfacet Screw Fixation: A Technique Analysis of 176 Screws in 83 Patients With Assessment of Radiographic Accuracy, Hardware Failure, and Complications.. Operative neurosurgery (Hagerstown, Md.). 2016. DOI: 10.1227/neu.0000000000001356.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.