MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ultrasmedbio.2024.10.004

Медицинская библиотека · Ultrasound in medicine & biology · 2024

Dyssynchronous Fetal Heart Failure in Maternal Diabetes: Evaluation with Speckle Tracking Echocardiography and Novel M-Mode Software.

Kühle Theresa M, Burgmair Angela, Schummers Georg, Möllers Mareike, Oelmeier Kathrin, De Santis Chiara, Köster Helen Ann, Möllmann Ute, Willy Daniela, Braun Janina, Albert Felix, Schmitz Ralf

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

This study aimed to investigate dyssynchronous heart failure in fetuses of mothers with diabetes mellitus (FDM) and fetal controls (FC) using two-dimensional speckle tracking echocardiography (2D-STE) and novel M-mode prototype software (PS).

METHODS

In this cohort study 174 fetuses were analyzed, 87 in the FDM-cohort and 87 gestational age-matched fetuses in the FC-cohort. A subgroup of 38 fetuses formed the final case group, with a high median frame rate of approximately 160 frames/s. Using 2D Cardiac Performance Analysis software (TOMTEC, Unterschleissheim, Germany) we measured global longitudinal strain (GLS). TOMTEC PS detected annular displacement by assessing an artificial M-mode on the previously generated tracking. Dyssynchrony (DYS) was calculated as the inter- and intraventricular difference in time to peak GLS or annular displacement.

RESULTS

Greater DYS was observed in all basal myocardial measurement sites and software between FDM-cohort compared to FC-cohort and no significant correlation was found between DYS measurements and gestational age. Intraventricular DYS between the basal segments was statistically significant (all p ≤ 0.036, Wald test of univariate regression models). The PS performed best in DYS measurements identifying right ventricular DYS as potentially predicting FDM (FDM: median, 18.5 (interquartile range [IQR], 13.9-25.0) ms vs. FC: median, 2.7 [IQR, 1.5-3.5] ms; p < 0.001).

CONCLUSION

Increased intraventricular DYS demonstrated an impact of maternal diabetes mellitus on fetal hearts independent of gestational age. The prototype M-mode method identified cardiac dysfunction with higher accuracy than the conventional analysis. High-quality echocardiographic image acquisition is imperative for clinical application of 2D-STE and related advanced technologies.

Для цитирования: Kühle Theresa M, Burgmair Angela, Schummers Georg, Möllers Mareike, Oelmeier Kathrin, De Santis Chiara, Köster Helen Ann, Möllmann Ute, Willy Daniela, Braun Janina, Albert Felix, Schmitz Ralf. Dyssynchronous Fetal Heart Failure in Maternal Diabetes: Evaluation with Speckle Tracking Echocardiography and Novel M-Mode Software.. Ultrasound in medicine & biology. 2024. DOI: 10.1016/j.ultrasmedbio.2024.10.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.