Acta anaesthesiologica Scandinavica · 2022
The role of mechanical ventilation in primary graft dysfunction in the postoperative lung transplant recipient: A single center study and literature review.
СтатьяОбзорНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Niroomand Anna, Qvarnström Sara, Stenlo Martin, Malmsjö Malin, Ingemansson Richard, Hyllén Snejana, Lindstedt Sandra
Аннотация
BACKGROUND: Primary graft dysfunction (PGD) is still a major complication in patients undergoing lung transplantation (LTx). Much is unknown about the effect of postoperative mechanical ventilation on outcomes, with debate on the best approach to ventilation.
AIM/PURPOSE: The goal of this study was to generate hypotheses on the association between postoperative mechanical ventilation settings and allograft size matching in PGD development.
METHOD: This is a retrospective study of LTx patients between September 2011 and September 2018 (n = 116). PGD was assessed according to the International Society of Heart and Lung Transplantation (ISHLT) criteria. Data were collected from medical records, including chest x-ray assessments, blood gas analysis, mechanical ventilator parameters and spirometry.
RESULTS: Positive end-expiratory pressures (PEEP) of 5 cm H2 O were correlated with lower rates of grade 3 PGD. Graft size was important as tidal volumes calculated according to the recipient yielded greater rates of PGD when low volumes were used, a correlation that was lost when donor metrics were used.
CONCLUSION: Our results highlight a need for greater investigation of the role donor characteristics play in determining post-operative ventilation of a lung transplant recipient. The mechanical ventilation settings on postoperative LTx recipients may have an implication for the development of acute graft dysfunction. Severe PGD was associated with the use of a PEEP higher than 5 and lower tidal volumes and oversized lungs were associated with lower long-term mortality. Lack of association between ventilatory settings and survival may point to the importance of other variables than ventilation in the development of PGD.
AIM/PURPOSE: The goal of this study was to generate hypotheses on the association between postoperative mechanical ventilation settings and allograft size matching in PGD development.
METHOD: This is a retrospective study of LTx patients between September 2011 and September 2018 (n = 116). PGD was assessed according to the International Society of Heart and Lung Transplantation (ISHLT) criteria. Data were collected from medical records, including chest x-ray assessments, blood gas analysis, mechanical ventilator parameters and spirometry.
RESULTS: Positive end-expiratory pressures (PEEP) of 5 cm H2 O were correlated with lower rates of grade 3 PGD. Graft size was important as tidal volumes calculated according to the recipient yielded greater rates of PGD when low volumes were used, a correlation that was lost when donor metrics were used.
CONCLUSION: Our results highlight a need for greater investigation of the role donor characteristics play in determining post-operative ventilation of a lung transplant recipient. The mechanical ventilation settings on postoperative LTx recipients may have an implication for the development of acute graft dysfunction. Severe PGD was associated with the use of a PEEP higher than 5 and lower tidal volumes and oversized lungs were associated with lower long-term mortality. Lack of association between ventilatory settings and survival may point to the importance of other variables than ventilation in the development of PGD.