Ultrasonic locating devices for central venous cannulation: meta-analysis.

Hind Daniel, Calvert Neill, McWilliams Richard, Davidson Andrew, Paisley Suzy, Beverley Catherine, Thomas Steven

СтатьяМетаанализПоддержка исследования: вне правительства СШАСистематический обзорПеревод в очереди

Аннотация

OBJECTIVES

To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation.

DATA SOURCES: 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature.

DESIGN

Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. INTERVENTION REVIEWED: Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation.

DATA EXTRACTION: Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation.

DATA SYNTHESIS: 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38).

CONCLUSIONS

Evidence supports the use of two dimensional ultrasonography for central venous cannulation.

Для цитирования: Hind Daniel, Calvert Neill, McWilliams Richard, Davidson Andrew, Paisley Suzy, Beverley Catherine, Thomas Steven. Ultrasonic locating devices for central venous cannulation: meta-analysis.. BMJ (Clinical research ed.). 2003. DOI: 10.1136/bmj.327.7411.361.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.