DOI 10.1164/rccm.201609-1848oc
The Timing of Early Antibiotics and Hospital Mortality in Sepsis.
Аннотация
RATIONALE: Prior sepsis studies evaluating antibiotic timing have shown mixed results.
OBJECTIVES
To evaluate the association between antibiotic timing and mortality among patients with sepsis receiving antibiotics within 6 hours of emergency department registration.
METHODS
Retrospective study of 35,000 randomly selected inpatients with sepsis treated at 21 emergency departments between 2010 and 2013 in Northern California. The primary exposure was antibiotics given within 6 hours of emergency department registration. The primary outcome was adjusted in-hospital mortality. We used detailed physiologic data to quantify severity of illness within 1 hour of registration and logistic regression to estimate the odds of hospital mortality based on antibiotic timing and patient factors.
MEASUREMENTS AND MAIN
RESULTS
The median time to antibiotic administration was 2.1 hours (interquartile range, 1.4-3.1 h). The adjusted odds ratio for hospital mortality based on each hour of delay in antibiotics after registration was 1.09 (95% confidence interval [CI], 1.05-1.13) for each elapsed hour between registration and antibiotic administration. The increase in absolute mortality associated with an hour's delay in antibiotic administration was 0.3% (95% CI, 0.01-0.6%; P = 0.04) for sepsis, 0.4% (95% CI, 0.1-0.8%; P = 0.02) for severe sepsis, and 1.8% (95% CI, 0.8-3.0%; P = 0.001) for shock.
CONCLUSIONS
In a large, contemporary, and multicenter sample of patients with sepsis in the emergency department, hourly delays in antibiotic administration were associated with increased odds of hospital mortality even among patients who received antibiotics within 6 hours. The odds increased within each sepsis severity strata, and the increased odds of mortality were greatest in septic shock.