MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jneumeth.2024.110350

Медицинская библиотека · Journal of neuroscience methods · 2024

Detecting fast-ripples on both micro- and macro-electrodes in epilepsy: A wavelet-based CNN detector.

Gardy Ludovic, Curot Jonathan, Valton Luc, Berthier Louis, Barbeau Emmanuel J, Hurter Christophe

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Fast-ripples (FR) are short (∼10 ms) high-frequency oscillations (HFO) between 200 and 600 Hz that are helpful in epilepsy to identify the epileptogenic zone. Our aim is to propose a new method to detect FR that had to be efficient for intracerebral EEG (iEEG) recorded from both usual clinical macro-contacts (millimeter scale) and microwires (micrometer scale).

NEW METHOD: Step 1 of the detection method is based on a convolutional neural network (CNN) trained using a large database of > 11,000 FR recorded from the iEEG of 38 patients with epilepsy from both macro-contacts and microwires. The FR and non-FR events were fed to the CNN as normalized time-frequency maps. Step 2 is based on feature-based control techniques in order to reject false positives. In step 3, the human is reinstated in the decision-making process for final validation using a graphical user interface.

RESULTS

WALFRID achieved high performance on the realistically simulated data with sensitivity up to 99.95 % and precision up to 96.51 %. The detector was able to adapt to both macro and micro-EEG recordings. The real data was used without any pre-processing step such as artefact rejection. The precision of the automatic detection was of 57.5. Step 3 helped eliminating remaining false positives in a few minutes per subject.

COMPARISON WITH EXISTING

METHODS

WALFRID performed as well or better than 6 other existing methods.

CONCLUSION

Since WALFRID was created to mimic the work-up of the neurologist, clinicians can easily use, understand, interpret and, if necessary, correct the output.

Для цитирования: Gardy Ludovic, Curot Jonathan, Valton Luc, Berthier Louis, Barbeau Emmanuel J, Hurter Christophe. Detecting fast-ripples on both micro- and macro-electrodes in epilepsy: A wavelet-based CNN detector.. Journal of neuroscience methods. 2024. DOI: 10.1016/j.jneumeth.2024.110350.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.