MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1537-2995.2009.02332.x

Медицинская библиотека · Transfusion · 2009

A novel rapid and effective donor arm disinfection method.

McDonald Carl, McGuane Siobhan, Thomas Julia, Hartley Stephen, Robbins Steve, Roy Anjana, Verlander Neville, Barbara John

Клиническое исследованиеСравнительное исследованиеСтатьяВалидационное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The aim of the study was to derive a donor arm disinfection technique that was rapid, but with a disinfection efficacy equivalent to a previous "best-practice" technique. This method consisted of a two-stage procedure with an initial application of 70% isopropyl alcohol and then 2% tincture of iodine (IATI). The total time for the IATI method was 2 minutes in duration. A rapid technique (1 min in duration) was needed to obviate potential problems due to increased donor waiting time, had the IATI method been implemented at blood donation sessions.

STUDY DESIGN AND

METHODS

A direct swabbing and plating technique was used to enumerate bacteria present before and after disinfection. In total, seven methods were evaluated.

RESULTS

The chlorhexidine/alcohol applicator (CAA) disinfection device containing 1.5 mL of 2% chlorhexidine gluconate and 70% isopropyl alcohol (99.91% reduction; confidence limits, 99.55%, 99.98%) was shown to have equivalent disinfection efficacy as the IATI method (99.89% reduction; confidence limits, 99.36%, 99.98%; p = 0.86). Procedural time for the 1.5-mL CAA method was 1 minute thereby avoiding potential problems of increased donor waiting time, inherent in the IATI 2-minute procedure at blood donation sessions.

CONCLUSIONS

The 1.5-mL CAA disinfection method offers blood services a rapid and effective donor arm disinfection procedure. In 2006, the 1.5-mL CAA procedure was implemented throughout the entire English blood service for all donations.

Для цитирования: McDonald Carl, McGuane Siobhan, Thomas Julia, Hartley Stephen, Robbins Steve, Roy Anjana, Verlander Neville, Barbara John. A novel rapid and effective donor arm disinfection method.. Transfusion. 2009. DOI: 10.1111/j.1537-2995.2009.02332.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.