MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.urolonc.2015.03.022

Медицинская библиотека · Urologic oncology · 2015

Reliability of dynamic sentinel node biopsy combined with ultrasound-guided removal of sonographically suspicious lymph nodes as a diagnostic approach in patients with penile cancer with palpable inguinal lymph nodes.

Naumann Carsten Maik, van der Horst Sibylle, van der Horst Christof, Kähler Katharina Charlotte, Seeger Markus, Osmonov Daniar, Lützen Ulf, Jünemann Klaus-Peter, Franz Hamann Moritz

СтатьяПеревод в очереди

Аннотация

INTRODUCTION AND

OBJECTIVES

Dynamic sentinel node biopsy (DSNB) is considered "unsuitable" in patients with penile cancer and palpable inguinal lymph nodes. The aim of this study was to determine the diagnostic reliability of DSNB combined with ultrasound (US)-guided removal of additional suspicious lymph nodes as a minimally invasive diagnostic approach in these patients.

MATERIAL AND

METHODS

A total of 23 consecutive patients with penile cancer and unilaterally or bilaterally palpable inguinal lymph nodes underwent DSNB according to the 2-day protocol. Before the combined staging procedure, the patients underwent preoperative US of both groins. During surgery, sentinel nodes and additional suspicious lymph nodes as determined by the US examination were removed under US guidance. A complete inguinal lymph node dissection was only performed in patients who had tumor-positive nodes. Follow-up consisted of control visits according to the European Association of Urology guidelines, including US investigation of the groins.

RESULTS

The primary tumors were staged as T1, T2, and T3 carcinomas in 12, 8, and 3 patients, respectively. Grading was good, moderate, and poor in 2, 16, and 4 cases, respectively. Tumor grading could not be determined in 1 patient who underwent surgery of the invasive part of the primary tumor elsewhere. Sentinel nodes or nonsentinel nodes or both were positive in 15 of 36 palpatory-positive groins. DSNB alone showed lymphatic spread in 10 inguinal regions. US-guided removal of suspicious nonsentinel nodes revealed 5 further inguinal basins with metastases, which would have been missed by DSNB owing to rerouting or complete blockage of the lymphotropic tracer. So far, no lymph node relapse has been observed in the 12 patients with node-negative disease by this combined diagnostic approach with a median follow-up of 42 (16-84) months. The morbidity (postoperative bleeding and prolonged lymphorrhea) associated with this procedure was minor (6%).

CONCLUSIONS

The results of this study imply that DSNB combined with US-guided removal of suspicious lymph nodes is a reliable diagnostic approach in patients with penile cancer with palpable inguinal lymph nodes. DSNB alone in these patients leads to a significant false-negative rate. These early and promising results have to be confirmed in larger cohort studies.

Для цитирования: Naumann Carsten Maik, van der Horst Sibylle, van der Horst Christof, Kähler Katharina Charlotte, Seeger Markus, Osmonov Daniar, Lützen Ulf, Jünemann Klaus-Peter, Franz Hamann Moritz. Reliability of dynamic sentinel node biopsy combined with ultrasound-guided removal of sonographically suspicious lymph nodes as a diagnostic approach in patients with penile cancer with palpable inguinal lymph nodes.. Urologic oncology. 2015. DOI: 10.1016/j.urolonc.2015.03.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.