Labor induction by transcervical balloon catheter and cerebral palsy associated with umbilical cord prolapse.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Yamada Takahiro, Cho Kazutoshi, Yamada Takashi, Morikawa Mamoru, Minakami Hisanori
Аннотация
AIM: The aim of this study was to determine whether the use of transcervical balloon catheter (TCBC) for induction of labor (IOL) is a risk factor for cerebral palsy (CP) associated with umbilical cord prolapse (UCP-CP) in singleton pregnancies with cephalic presentation.
MATERIAL AND METHODS: Among all 102 infants with CP who were preliminarily determined as caused by antenatal and/or intrapartum hypoxemia by the Japan Council for Quality Health Care until April 2012, all 56 infants who met all of the following criteria were studied: cephalic singleton pregnancy, reassuring fetal status on electronic cardiotocogram at time of admission to obstetric facilities for labor pains, ruptured fetal membranes, and/or IOL, and hypoxic-ischemic encephalopathy at birth. Clinical backgrounds were compared between six infants with UCP-CP and the remaining 50 infants with CP not associated with UCP (non-UCP-CP).
RESULTS: Frequencies of IOL (83% [5/6] vs 32% [16/50], P = 0.0236), use of TCBC (67% [4/6] vs 10% [5/50], P = 0.0044), and amniotomy (67% [4/6] vs 24% [12/50], P = 0.0494) were significantly higher in the UCP-CP than the non-UCP-CP group. Only TCBC was a risk factor significantly associated with UCP-CP after logistic regression analysis, yielding an odds ratio of 18.0 (95% confidence interval, 2.6-124; P = 0.003). Saline volumes of 80-150 mL were used for TCBC inflation in the four UCP-CP patients.
CONCLUSION: Use of TCBC with a saline volume ≥ 80 mL was a significant risk factor for UCP-CP; however, the absolute risk of UCP-CP was estimated to be very low, approximately one in 7875 TCBC users.
MATERIAL AND METHODS: Among all 102 infants with CP who were preliminarily determined as caused by antenatal and/or intrapartum hypoxemia by the Japan Council for Quality Health Care until April 2012, all 56 infants who met all of the following criteria were studied: cephalic singleton pregnancy, reassuring fetal status on electronic cardiotocogram at time of admission to obstetric facilities for labor pains, ruptured fetal membranes, and/or IOL, and hypoxic-ischemic encephalopathy at birth. Clinical backgrounds were compared between six infants with UCP-CP and the remaining 50 infants with CP not associated with UCP (non-UCP-CP).
RESULTS: Frequencies of IOL (83% [5/6] vs 32% [16/50], P = 0.0236), use of TCBC (67% [4/6] vs 10% [5/50], P = 0.0044), and amniotomy (67% [4/6] vs 24% [12/50], P = 0.0494) were significantly higher in the UCP-CP than the non-UCP-CP group. Only TCBC was a risk factor significantly associated with UCP-CP after logistic regression analysis, yielding an odds ratio of 18.0 (95% confidence interval, 2.6-124; P = 0.003). Saline volumes of 80-150 mL were used for TCBC inflation in the four UCP-CP patients.
CONCLUSION: Use of TCBC with a saline volume ≥ 80 mL was a significant risk factor for UCP-CP; however, the absolute risk of UCP-CP was estimated to be very low, approximately one in 7875 TCBC users.