MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/s20082268

Медицинская библиотека · Sensors (Basel, Switzerland) · 2020

Wireless Motion Sensors-Useful in Assessing the Effectiveness of Physiotherapeutic Methods Used in Patients with Knee Osteoarthritis-Preliminary Report.

Goślińska Jagoda, Wareńczak Agnieszka, Miedzyblocki Margaret, Hejdysz Krystyna, Adamczyk Ewa, Sip Paweł, Chlebuś Ewa, Gośliński Jarosław, Owczarek Piotr, Woźniak Adam, Lisiński Przemysław

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

Osteoarthritis of the knee (OAK) is characterized by pain, limitation of joint mobility, and significant deterioration of proprioception resulting in functional decline. This study assessed proprioception in OAK patients following two ten-day rehabilitation programs using the Orthyo® system. Fifty-four study participants with clinical symptoms and radiological signs of OAK were randomly divided into an exercise group (n = 27) or a manual therapy group (n = 27). The control group consisted of 27 volunteers with radiological signs of OAK, but with no clinical symptoms or prior history of rehabilitation. The following parameters were assessed: knee proprioception using inertial sensors and a mobile application, patients' function using Western Ontario and McMaster Universities osteoarthritis index (WOMAC), and pain intensity using the visual analog scale (VAS). Following rehabilitation, knee proprioception tests did not improve in either study group. Both study groups showed significant improvement of the WOMAC-assessed function (exercise group: p < 0.01, manual therapy group: p = 0.01) and a significant decrease (p < 0.01) of VAS-assessed pain following rehabilitation, but the post-therapy results did not differ significantly between the aforementioned groups. The Orthyo® system provided a quick and accurate assessment of the knee joint position sense. There was no direct relationship between functionality, pain, and proprioception threshold in the knee joint.

Для цитирования: Goślińska Jagoda, Wareńczak Agnieszka, Miedzyblocki Margaret, Hejdysz Krystyna, Adamczyk Ewa, Sip Paweł, Chlebuś Ewa, Gośliński Jarosław, Owczarek Piotr, Woźniak Adam, Lisiński Przemysław. Wireless Motion Sensors-Useful in Assessing the Effectiveness of Physiotherapeutic Methods Used in Patients with Knee Osteoarthritis-Preliminary Report.. Sensors (Basel, Switzerland). 2020. DOI: 10.3390/s20082268.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.